Step 4. FIELD WIRING

CAUTION: Label all wires prior to discon-
nection when servicing controls. Wiring
errors can cause improper and dangerous
operation.
ATTENTION: Au moment de l'entretien
des commandes, étiquetez tous les fils
avant de les débrancher. Des erreurs
de cáblage peu-vent entraîner un fonc-
tionnement inadéquat et dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adé-
quatement une fois l'entretien terminé.
CAUTION
Ground supply lead must be connect-
ed to the wire attached to the green
ground screw located on the outlet
box. See Figures 34 and 35. Failure to
do so will result in a potential safety
hazard. The appliance must be elec-
trically grounded in accordance with
local codes or, in the absence of local
codes, the National Electrical Code,
ANSI/NFPA 70-latest edition.
(See Figure 35 for detailed drawing
of junction box / receptacle wiring.)
Junction Box
Hot
Neutral
120V AC
Ground
G
B
W
Wall Receiver
Hi-Temp Sleeve
Cable Harness 102661-01
Wiring Color Code
B = Black
BR = Brown
BL = Blue
G = Green
Figure 34: Electronic Wiring Diagram for Gravity Vent Fireplaces
Electronic Wiring
(See Figures 34 and 35)
Note: The electronic appliance must be
connected to the main power supply.
1. Route a 3-wire, 120 Vac, 60 Hz, 1ph power
supply to the appliance junction box.
2. Remove the electrical inlet cover plate from
the side of the unit by removing the plate's
securing screws (see Figure 13, Page 12).
3. Remove the cover plate's knockout and then
feed the power supply wire through the
knockout opening and into the unit junction
box.
4. Connect the black power supply wire to the
power outlet's red pigtail lead and the white
Green
Ground
Screw
Figure 35: Junction Box Wiring
ELECTRONIC WIRING DIAGRAM FOR GRAVITY VENT FIREPLACES
AC/DC
Power Adaptor
GY
R
B
BR
O
Y
W
G
BL
PU
GY = Gray
PU = Purple
R = Red
O= Orange
W = White
Y = Yellow
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Green
White
Tab Intact
Tab Intact
hot
Side of
Neutral
Receptacle
Side of
Receptacle
B
BR
Y
O
O
G
Proflame Valve
Y
Electronic Modulation
DFC Wire Harness 102662-01
G
W
THIS CONNECTOR NOT
USED ON GRAVITY
VENT UNITS
power supply wire to the common terminal
of the outlet as shown in Figures 34 and 35.
5. Connect the ground supply wire to the pig-
tail lead attached to outlet's green ground
screw.
6. After wiring is complete, replace the cover
plate.

Step 5. REMOVE GLASS DOOR

ASSEMBLY (ON CONTROL SIDE)
If not already done, remove the glass door
assembly on the control side of the fireplace
(see Page 29).
Junction Box
J-BOX / RECEPTACLE
Black
WIRING
120V, 60hZ, 1Ph
Field Wired
Factory Wired
Electronic Pilot Assembly
Igniter Rod
Hood
B
Pilot
R
Tube
Y
Pilot
Ground
Wire
Y
G
O
W
W
G
BL
PU
Unit Mounted Rocker Switch
OFF (o) = Intermittent Pilot Mode
ON (-) = Standing Pilot Mode
Ground - Green
Neutral - White
120 VAC - Black
Flame
Sensor
Spark Wire Cable
Pilot Sensor Cable
Proflame
DFC Board
23