EMGA TLC 1598 User Manual

General purpose thermometer

Advertisement

926.002 DIGITAL THERMOMETER - MANUAL
®
General purpose thermometer
TLC 1598
926002 en ma 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TLC 1598 and is the answer not in the manual?

Questions and answers

Summary of Contents for EMGA TLC 1598

  • Page 1 926.002 DIGITAL THERMOMETER - MANUAL ® General purpose thermometer TLC 1598 926002 en ma 2013...
  • Page 2: En Ma 2013 926002 En Ma

    TLC 1598 English Please read this manual carefully before operating your new general purpose thermometer. The operating manual introduces you with clear and simple instructions to the hand- ling of the thermometer. Information that are useful and important for understanding the function, are highlighted in the instructions text.
  • Page 3: Table Of Contents

    TLC 1598 English Contents list Description ......7 Extent of supply ....7 Operation ......9 3.1 Switching on the thermometer ..9 3.2 Temperature measuring ....9 Troubleshooting ....11 Calibration service ... 13 Appendix ........15 Accessories ....... 15 Technical data ......
  • Page 4: Description

    TLC 1598 English Description The general purpose thermometer is a handy measuring instrument operated with a lithium battery, used to measure the temperature of air, liquids and plastic material (meat, fruit, etc.) The electronics are controlled by a micro- processor. This ensures a high measuring precision and linearity over the complete measuring range.
  • Page 5: Operation

    TLC 1598 English Parts list: thermometer calibration certificate for accessories see appendix I Operation 3.1 Switching the thermometer To switch the thermometer on, press the ”ON/OFF” button for at least one se- cond. The device will perform a system test during which all segments are visible in After this the measuring channel is tested.
  • Page 6: Troubleshooting

    TLC 1598 English Use the probe only as directed, in order to avoid damages and faulty measurements. When the measurement is finished, switch the device off by pressing “ON/ OFF”. Troubleshooting 926002 en ma 2013 926002 en ma 2013...
  • Page 7: Calibration Service

    TLC 1598 English Calibration services In order to guarantee a high measuring precision, the thermometer must be cali- brated every year. Therefore ebro Electronic GmbH & Co. KG offers a calibration service. Fill in the enclosed service card. After one year we will recall your ther- mometer for calibration.
  • Page 8: Appendix

    TLC 1598 English Appendix Accessories Description Identifier Artificial leather case EB 5 L Plastic box, blue EB 1598 Technical data Measuring range ... -50 to +200 °C Sensor ......Pt 1000 Operating temperature . 0 to +50 °C Storage temperature ..-10 to +60 °C Resolution ....
  • Page 9 D-85055 Ingolstadt erklärt in alleiniger Verantwortung, dass das Produkt declares in sole responsibility that the product déclare sous sa seule responsabilité que le produit Geräteart: Thermometer Typ: TLC 1598 Type of device: Thermometer Type: Type d‘appareil: Thermomètre Modèle: mit den folgenden Normen oder normativen Dokumenten überein-...