Page 1
DVI - to - VGA Video Scaler Converts Digital DVI to Analog VGA or HDTV Component Output With programmable output Resolution ! UMA1061 Rev. n/c December 8, 2005 Order toll-free in the U.S. 800-959-6439 CUSTOMER FREE technical support, Call 714-641-6607 or fax 714-641-6698 SUPPORT Mail order: Hall Research Technologies, 1163 Warner Ave., Tustin, CA 92780 INFORMATION...
Page 3
DVI - to - VGA Video Scaler TRADEMARKS USED IN THIS MANUAL Hall Research, HRT, and (logo) are trademarks of Hall Research Technologies, Inc. IBM is a registered trademark of International Business Machines Corporation. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
The controls include input/output setup picture adjustment, H/V phase adjustment, System information and many other advance options. The SC-DV-2 allows you to specify a resolution and refresh rate for it's output. Then it will output a steady (uninterrupted) VGA signal to your display device at the specified rate regardless of the input.
2. Installation 2.1 Input connection: The SC-DV-2 can accept both PC and HDTV input in digital DVI format. Use the DVI-to-DVI cable to connect the DVI output of a PC or HDTV device to the DVI input connector of the SC-DV-2.
SC-DV-2 to the YPbPr input of a HDTV device. 2.3 Connection Block Diagrams In the above diagrams the output of the SC-DV-2 connects to the VGA monitor via a HD15 Cable and to the HDTV via a HD15 to 3 RCA cable.
ü YPBPR … The SC-DV-2 automatically detects and shows the input format as YPbPr or RGB. However, you can manually select the YPbPr or RGB to match the format of your input. Selecting a format that doesn't coincide with your input will result in an abnormal picture.
Page 9
When it is selected, it shows the input/output resolution and their vertical refresh rate on the screen. When it is selected the SC-DV-2 will automatically adjust all the parameter to the factory preset value. Select to exit from the current menu page.
Contacting Hall Research Technologies If you determine that your scaler is malfunctioning, do not attempt to repair the unit. Contact HRT’s Tech. Support at 714-641-6607. Before you do, make a record of the history of the problem. We will be able to provide more efficient and accurate assistance if you have a complete description.
Model SC-DV-2 Reference Information DVI Connector pinout N/U = Not Used Signal name Signal name TMDS Data2– TMDS Data3+ (N/U) TMDS Data2+ +5V Power TMDS Data2/4 Shield Ground for +5V Power TMDS Data4– (N/U) Hot Plug Detect TMDS Data4+ (N/U) TMDS Data0–...
Need help?
Do you have a question about the SC-DV-2 and is the answer not in the manual?
Questions and answers