Mounting The Boiler - Lochinvar Knight WHN055 Installation & Operation Manual

Wall mount boiler
Table of Contents

Advertisement

2
Prepare boiler
13. Reattach the Molex plug to the gas valve.
14. Models 55 - 285 only, turn the gas valve power switch to
the "ON" position.
15. Model 399 only, turn on power at the source.
16. After the installation is complete, fill out the gas conversion
label (in the conversion kit bag) and affix it to the unit
under the boiler rating plate inside the unit. Attach the
LP caution label (in the conversion kit bag) to the left side
of the unit in the lower left corner.
17. Replace the front access cover.
After converting to LP, check combustion
WARNING
per the Start-up procedure in Section 10
of this manual. Failure to check and
verify combustion could result in severe
personal injury, death, or substantial
property damage.
Figure 2-3 Installing Propane Orifice
GROMMET
BRASS ORIFICE
SCREWS
VENTURI

Mounting the boiler

See page 9 of this manual for boiler mounting location
instructions.
The Knight Wall Mount boiler is not
NOTICE
intended for floor installation.
Mounting to a wood studded wall:
1.
The wall mount bracket is designed for a stud spacing of
16 inches from center. For other stud spacing a solid
mounting surface must be provided by the installer.
WARNING Do not mount the boiler to a hollow wall.
Be sure to mount the boiler to the studs
only.
2.
Mount the wall bracket using the 2 1/4" lag bolts
provided. Make sure the top edge of the bracket is away
from the wall. Ensure the bracket is level when mounted.
Extreme care is needed to ensure the bolts are secured in
the center of the studs.
3.
Hang the boiler on the bracket and secure the bottom of
the boiler with two (2) additional lag bolts provided.
(continued)
GAS VALVE
Installation & Operation Manual
WARNING The boiler is too heavy for a single person to
lift. A minimum of two people is needed for
mounting the boiler onto the bracket.
Mounting to a concrete wall:
1.
Mount the wall bracket using the two (2) wedge anchor
bolts provided with the bracket. To mount the wedge
anchor bolts, drill a 1/4" diameter hole 1 1/8" deep and
insert anchor. Hang the bracket from the anchor and secure
with the two nuts provided. Make sure the top edge of the
bracket is away from the wall. Ensure bracket is level when
mounted. Extreme care is needed to ensure the bolts are
secured in the center of the studs.
Note: If wall thickness does not allow a 1 1/8" deep hole,
field supplied hardware suitable for the application should be
provided.
2.
Hang the boiler on the bracket and secure the bottom of the
boiler with two (2) remaining anchors, following the
instructions above.
The boiler is too heavy for a single person to
WARNING
lift. A minimum of two people is needed for
mounting the boiler onto the bracket.
Mounting to a metal studded wall:
1.
The wall mount bracket is designed for a stud spacing of
16 inches from center. For other stud spacing a solid
mounting surface must be provided by the installer.
Do not mount the boiler to a hollow wall. Be
WARNING
sure to mount the boiler to the studs only.
2.
Mount the wall bracket using two (2) field supplied toggle
bolts capable of supporting 100 pounds each. Ensure the
top edge of the bracket is away from the wall. Ensure the
bracket is level when mounted. Extreme care is needed to
ensure the bolts are secured in the center of the studs.
3.
Hang the boiler on the bracket and secure the bottom of the
boiler with two (2) field supplied toggle bolts.
WARNING The boiler is too heavy for a single person
to lift. A minimum of two people is needed
for mounting the boiler onto the bracket.
Figure 2-4 Mounting the Boiler
FASTENERS
APPROPRIATE
FOR WALL TYPE
QTY: 4
WALL:
WOOD OR METAL STUDS ON
16" CENTERS -OR-
MASONRY / POURED CONCRETE
MOUNTING BRACKET
(FACTORY SUPPLIED)
13