Anytime any maintenance or repairs are done (including clearing jams), FIRST:
1.
Disconnect the Nailer from the air hose.
2.
Empty the Nail Canister (100) completely.
3.
Attempt to fire the Nailer into a piece of scrap wood to ensure that it is dis-
connected and is incapable of firing any nails.
4.
Rotate the Trigger Lock (28) to its locked position as shown on page 6.
1.
Occasionally a nail may become jammed in the firing mechanism of the Nailer,
making the tool inoperable.
2.
To remove a jammed nail, rotate the Trigger Lock (28) to the locked position and
disconnect the Nailer from its compressed air supply. Empty the Nail Canister (100)
completely of nails. Ulock the Trigger Lock and attempt to fire the Nailer into a piece
of scrap wood to ensure it is disconnected and is incapable of firing any nails.
3.
Relock the Trigger Lock (28) and use a pair of needle nose pliers (not included) to
remove the jammed nail (usually from the Feed Pawl (87) area).
4.
Unlock the Trigger Lock and press the Safety (59) against a piece of scrap wood.
5.
Test fire the Nailer several times, checking for proper operation.
6.
If the Nailer is properly firing, you can continue to use the Nailer. Rotate the Trigger
Lock (28) to the locked position, disconnect the air supply to the Nailer, and reload
the Nails. Then, reconnect the air supply, disengage the Trigger Lock (28), and
continue working.
7.
When finished working, rotate the Trigger Lock (28) to the locked position and
disconnect the air supply. Remove the Nails. Then, store the Nailer and nails in a
location out of children's reach.
DOOR
LATCH (32)
DOOR
(34)
SKU 92918
For technical questions, please call 1-800-444-3353.