Multiglow Fires Classic II Quattro Installation, Servicing And User Instructions Manual

Multiglow fires decorative fuel effect appliances for use with natural gas

Advertisement

CLASSIC II
QUATTRO
DECORATIVE FUEL EFFECT APPLIANCES FOR USE WITH
NATURAL GAS
IIN
INSTALLATION, SERVICING & USER
INSTRUCTIONS
THESE INSTRUCTIONS MUST BE LEFT WITH THE USER
MANUFACTURED BY:
MULTIGLOW FIRES
Canterbury Road, St. Nicholas-At- Wade.
Kent. CT7 0PQ
MULTIGLOW
FIRES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Classic II Quattro and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Multiglow Fires Classic II Quattro

  • Page 1 CLASSIC II QUATTRO DECORATIVE FUEL EFFECT APPLIANCES FOR USE WITH NATURAL GAS INSTALLATION, SERVICING & USER INSTRUCTIONS THESE INSTRUCTIONS MUST BE LEFT WITH THE USER MANUFACTURED BY: MULTIGLOW FIRES Canterbury Road, St. Nicholas-At- Wade. Kent. CT7 0PQ MULTIGLOW FIRES...
  • Page 2 INDEX SECTION 1. CONFORMITY AND GENERAL NOTES (INSTALLER) SECTION 2. TECHNICAL DATA (INSTALLER) SECTION 3. INSTALLATION PARAMETERS (INSTALLER) SECTION 4. PRE-INSTALLATION CHECK (INSTALLER) SECTION 5. INSTALLATION (INSTALLER) SECTION 6. REMOTE CONTROL (INSTALLER & END USER) SECTION 7. FUNCTION CHECKS & COMMISSIONING (INSTALLER) SECTION 8.
  • Page 3 CONFORMITY & GENERAL NOTES SECTION 1 Because Multiglow Fires believe in the use of modern technology and materials, they reserve the rights to modify or change the layout and controls of their burner trays, at any time, whilst still complying with current specifications.
  • Page 4: Technical Data

    use with solid fuel appliances) is therefore recommended where the young, elderly or infirm are concerned. NOTE: The larger of the units manufactured have gas consumption similar to that of a small boiler (i.e.50000 BTU). Therefore, it is essential that the gas supply pipe work be of a size that will allow for the correct flow rate (See TECHNICAL DATA for required information).
  • Page 5: Pre-Installation Check

    Regulations applicable to the country of use. In addition, the installation must be carried out in-accordance with the relevant and current local and national specifications and building regulations. The fireplace surround, hearth and builders opening shall be of non-combustible material. Hearth and clearance dimensions must comply with the requirements of BS 5071 part 3.
  • Page 6: Gas Soundness

    They are installed so that every part of any flame or incandescent material will be at least 225mm Above the floor B. The manufacturers instructions state that a Hearth is not required Multiglow Fires recommend that a hearth or physical barrier is installed with this appliance...
  • Page 7: Contents Checklist

    However should you decide not to follow the recommendation and do not fit a hearth or barrier or decide to remove one or both. Then consideration as to the safety of the occupants of the room should be given. CONTENTS CHECKLIST 1.
  • Page 8: Fixing Holes

    6. Place the box centrally into the opening. 7. Whilst holding the box in place, mark the appropriate holes in the base and roof of the box. 8. Remove the box, drill and plug the respective positions. 9. Replace box and fix with screws supplied. 10.
  • Page 9 too much force. 14. Purge the gas supply pipe work to remove air and debris BEFORE connection of the fire. The 8mm pipe should be used to connect valve to an isolating tap, which must be adjacent to the appliance (so that when tap is closed appliance is totally isolated). NOTE Soft soldered joints should not be used beneath the burner tray.
  • Page 10: Remote Control

    SECTION 6. REMOTE CONTROL...
  • Page 20: Section 8. Final Check & Customer Briefing

    SECTION 7. FUNCTION CHECKS & COMMISSIONING Check that the valve and remote control are all functioning properly. If there is a problem double check the trouble shooting guide in section 6. REFERENCE PRESSURE The appliance is pre-set to the given heat input for the inlet pressure given on the Data Plate.
  • Page 21 8.3 Instruct the customer that the pilot and flame-sensing device fitted to this fire also acts as an atmospheric sensing device, which shuts off the appliance if the evacuation of the products of the combustion is interrupted. If the fire shuts off, restart the main burner as stated in section 6. If the appliance fails to relight or repeatedly cuts off, then do not use and inform a qualified person.
  • Page 22: General Maintenance

    Turn off gas supply before commencing any servicing. Always check for gas soundness and spillage after refitting the appliance. 9.1 GENERAL MAINTENANCE At yearly intervals, turn off and allow to cool down. Check all refractories, pilot burner/ignition unit, for soot or debris deposits. Theses can cause imperfect flame appearance and should be removed by brushing with a soft brush (DO NOT USE A VACUUM CLEANER).
  • Page 23 FIG 1 FIG 2 FIG 3 FIG 4 FIG 1, LAYER 1 FIG 2, LAYER 2 1 X LARGE PIECE OF DRIFTWOOD 1 X MED/LARGE PIECE OF 3 X ROW OF 6 PEBBLES DRIFTWOOD FIG 3, LAYER 3 FIG 4, LAYER 4 4 X MED PIECES OF DRIFTWOOD 4 X MED PIECES OF DRIFTWOOD...
  • Page 24: Installation Date

    PLEASE FILL IN INFORMATION BELOW FOR FUTURE REFERENCE INFORMATION CAN BE FOUND ON THE DATA PLATE MODEL SERIAL NUMBER INSTALLER INSTALLATION DATE MODEL DATE SERIAL NO WARRANTY INFORMATION If within the period of one year of purchase there is the unlikely occurrence of defect in either materials or workmanship Multiglow will arrange to repair or replace the item free of charge.