<Heating> (Continued)
No. of
Temperature condition
operating
units
Indoor
Outdoor
3 units
20/-
7/6
NOTES:
1. Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent. (Thermistor
thermometer)
2. Connecting piping condition : 5 meters × 3 units (5 m / each indoor unit)
Standard
Indoor unit
pressure
A
B
C
P (MP)
22
16
07
2.5 to 2.7
24
16
07
2.5 to 2.7
10
10
10
2.3 to 2.5
13
10
10
2.3 to 2.5
16
10
10
2.5 to 2.7
18
10
10
2.5 to 2.7
22
10
10
2.5 to 2.7
24
10
10
2.5 to 2.7
13
13
10
2.5 to 2.7
16
13
10
2.5 to 2.7
18
13
10
2.5 to 2.7
22
13
10
2.5 to 2.7
24
13
10
2.5 to 2.7
16
16
10
2.5 to 2.7
18
16
10
2.5 to 2.7
22
16
10
2.5 to 2.7
24
16
10
2.5 to 2.7
13
13
13
2.5 to 2.7
16
13
13
2.5 to 2.7
18
13
13
2.5 to 2.7
22
13
13
2.5 to 2.7
24
13
13
2.5 to 2.7
16
16
13
2.5 to 2.7
18
16
13
2.5 to 2.7
22
16
13
2.5 to 2.7
24
16
13
2.5 to 2.7
16
16
16
2.5 to 2.7
18
16
16
2.5 to 2.7
22
16
16
2.5 to 2.7
Heat exchanger
pipe temperature
T1 (ºC)
T2 (ºC)
37 to 39
-2 to 0
37 to 39
-2 to 0
38 to 40
-1 to 1
38 to 40
-1 to 1
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
37 to 39
-2 to 0
– 43 –
Compressor
Indoor fan
Outdoor fan
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
revolution
(rps)
73.0
73.0
71.8
72.2
72.4
72.6
72.8
73.0
72.6
72.8
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0
73.0