4. Removing the optical mechanism unit

4-1. Remove the six optical mechanism unit lock screws. Lift the unit off the position.
4-2. Remove the two lamp socket holder lock screws and take out the holder.
4-1
Duct Fan Unit
4-2
Optical Mechanism Unit