American Water Heater SRCC OG-300 Instruction Manual page 35

Residential solar water heating systems
Table of Contents

Advertisement

PROBLEM
Not enough hot water (cont.)
No hot water in the morning
Water too hot
No water
Pump does not start
CHECK THIS
Differential Controller
Isolation valves
Thermostatic mixing valve
Piping
Pump
Storage water heater
Differential controller
Thermostatic mixing valve
Cold-water supply valve
Differential controller
POSSIBLE CAUSE
Improper wiring or loose
connections)
Closed
Improper adjustment
Valve defective
Insuffi cient Insulation
High heat losses
Nighttime thermosyphoning
Improperly plumbed
Flow blockage
Low system pressure
No power
Flow rated too high or too low
Faulty pump
Runs continuously
Circuit breaker shut off
Sensor wires reversed
Improper adjustment
Valve defective
Valve closed
Controller set to "off" position
Unplugged
On and/or off temperature
differential set points too high
Loose contacts
Blown fuse
35
CORRECTIVE ACTION
Compare with system
schematic. Check for proper
connections. Seal all splices
against moisture
Open
Check water temperature at
house faucet and adjust valve
setting
Replace. System must not
be run without thermostatic
mixing valve due to scald risk.
Add insulation where required
Check insulation for splits,
deterioration, absence
Check for pump operation at
night
Compare with system
schematic. Check fl ow
direction
Flush system. Check effl uent
for debris.
Check pressure gauge. Set
system pressure to correct
setting, check for leaks.
Check breaker, pump cord,
and controller fuse. Repair or
replace
Adjust fl ow rate
Listen for irregular noises
in pump operation. Feel
collector feed and return line
for temperature difference.
Ensure all air is purged from
system.
Check sensors for shorts
Turn breaker on
Ensure the collector and
tanks sensors are wired to
the correct position on the
controller
Check water temperature at
house faucet and adjust valve
setting
Replace. System must not
be run without thermostatic
mixing valve due to scald risk.
Open valve
Set system operation to
"Auto"
Return power to controller
Reset on and off
differentials according to
recommendations
Clean contacts and tighten
connections or replace
Replace fuse