The names of the programs as well as all copyrights relating to the programs are the sole property of Viola Systems. Any transfer, licensing to a third party, leasing, renting, transportation, copying, editing, translating, modifying into another programming language or reverse engineering for any intent is forbidden without the written consent of Viola Systems.
Hardware Manual Arctic AMR Hardware Manual Declaration of Conformity (according to ISO/IEC Guide 22 and EN 45014) Manufacturer’s Name: Viola Systems Ltd. Manufacturer’s Address: Lemminkäisenkatu 14-18 A FI-20520 Turku Finland declares that this product: Product Name: Arctic AMR conforms to the following standards:...
Hardware Manual Arctic AMR Hardware Manual Revisions Date Document Firmware Description of changes Version Version 12/2010 Cable shield images added. Firmware Version 1.x Document Version 1.1...
Hardware Manual Arctic AMR Hardware Manual Contents COPYRIGHT AND TRADEMARK ..................2 DISCLAIMER..........................3 DECLARATION OF CONFORMITY..................4 WARRANTY AND SAFETY INSTRUCTIONS...............5 REVISIONS..........................6 1. INTRODUCTION....................... 8 Safety Operation........................8 2. HARDWARE........................9 Power supply......................... 9 Antenna connector......................10 System status LEDs......................10 Serial port..........................
Arctic AMR Hardware Manual 1 Introduction Arctic AMR is an intelligent GPRS modem device for AMR connectivity. The device has an integrated 1/3 phase AC power supply and GPRS connectivity. Intended audience for this manual are engineers and technical staff planning and commissioning the devices to field operations.
3. Antenna connector (SMA) 4. System status LEDs Figure 1. Physical Interface 2.1 Power supply Arctic AMR operates with external AC power. The power supply can be used in 1 or 3 phase configuration. Table 1: Power supply range Voltage range...
Hardware Manual Arctic AMR Hardware Manual Note! External fuses are required for each phase line to protect the device. The fuse with a rating not greater than 2A is recommended. All the connections to the power connector (phase and neutral) must be connected via all-pole safety switch.
Hardware Manual Arctic AMR Hardware Manual 2.5 Device identification and product label The device can be identified on product label. The device has a unique serial number as shown in the figure 2. Figure 2. Unique serial number Firmware Version 1.x...
Arctic AMR is delivered in a bulk package containing the device itself, antenna, cable clamp, cable shield and torx screws for back panel mounting. If any of the items are missing or are damaged, please contact Viola Systems Ltd. All packaging materials are recyclable. Viola Systems urges its customers to follow environmental regulations regarding the disposal of all materials.
Page 13
Hardware Manual Arctic AMR Hardware Manual Figure 3. Before SIM Installation When the device is opened, gently push and slide SIM holder for opening the cover. Insert the SIM card to the cover of the holder and close the SIM holder in the reversed order.
Page 14
Hardware Manual Arctic AMR Hardware Manual Figure 5. SIM card inserted and SIM holder closed Firmware Version 1.x Document Version 1.1...
Hardware Manual Arctic AMR Hardware Manual 3.3 Connecting power cable Warning! If the device has already been powered, wait for 5 minutes after all the LEDs have been disabled before opening the device. ■ When the device is opened, connect phase and neutral cables to power connector.
Page 16
Hardware Manual Arctic AMR Hardware Manual Table 4: Power connector Neutral Phase 1 Phase 2 Phase 3 Figure 7. Cable Tightening ■ Securely tighten cables to the power connector as shown in figure 7. Figure 8. Cable Gland Firmware Version 1.x...
Hardware Manual Arctic AMR Hardware Manual Note! Cable gland must be securely connected to prevent cable damage. 3.4 Mounting the back panel Insert the device back panel and tighten torx screws on bottom of the device (4 pcs torx T10).
(figure 8). 3.5 Mounting the device Arctic AMR device can be mounted by using the mounting holes in the back panel. With these holes, the device can be mounted on a flat surface, for example a cabinet.
Hardware Manual Arctic AMR Hardware Manual 4 Specifications Table 5: Specifications Product name Arctic AMR Product code 2170 Input voltage (Phase – Phase) 90-440 VAC Input voltage (Phase – N) 52-254 VAC Power consumption <5W Weight 0.3 kg GSM/GPRS Frequency band Quad band, 800, 900, 1800 and 1900 MHz Firmware Version 1.x...
Your sole and exclusive remedy for a covered defect is repair or replacement of the defective product, at Viola Systems’ sole option and expense, and Viola Systems may use new or refurbished parts or products to do so. If Viola Systems is unable to repair or replace a defective product, your alternate exclusive remedy shall be a refund of the original purchase price.