PD Technology 350 Instruction Manual

Power series domestic, commercial & industrial

Advertisement

Quick Links

www.garagedoorsonline.co.uk
PDT Power Series Instruction Manual
Domestic, Commercial & Industrial
PLEASE READ THE INSIDE FRONT COVER BEFORE INSTALLING THE
350, 500, 650 and 1000 MODELS
P D Technology Ltd 'Controlling The Future'
www.garagedoorsonline.co.uk
01926 463888
P D Technology Ltd
PDT POWER SERIES
01926 463888
www.garagedoorsonline.co.uk
www.garagedoorsonline.co.uk

Advertisement

Table of Contents
loading

Summary of Contents for PD Technology 350

  • Page 1 P D Technology Ltd PDT Power Series Instruction Manual Domestic, Commercial & Industrial PLEASE READ THE INSIDE FRONT COVER BEFORE INSTALLING THE PDT POWER SERIES 350, 500, 650 and 1000 MODELS P D Technology Ltd ‘Controlling The Future’ www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk...
  • Page 2 www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk IMPORTANT WIRING INFORMATION: Before installing the Battery Back Up System please pay attention to the information given below. Incorrect Installation will cause the Battery Back Up System to function incorrectly and may result in damage to the Battery Back Up. CORRECT INSTALLATION METHOD: P D TECHNOLOGY MAINS POWER...
  • Page 3: Table Of Contents

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk CONTENTS IMPORTANT SAFETY INSTRUCTIONS 2 - 3 Front View of PDT Power Series Rear View of PDT Power Series WHAT’S INCLUDED INSTALLATION CONTROLS AND INDICATORS ON/OFF/Alarm Silence Button Status Indicators: Mains, Battery, Fault, Standby Mains Indicator (Green/Amber) Battery Indicator (Green/Amber) Fault Indicator (Red/Green) Standby Indicator (Red)
  • Page 4: Important Safety Instructions

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions that should be followed during the installation and maintenance of the Uninterruptible Power System (UPS) and its batteries. Please read this manual thoroughly before attempting to install or operate this UPS. Read all safety, installation, and operating instructions before operating the UPS.
  • Page 5 www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk CAUTION BATTERY HANDLING PRECAUTIONS Servicing batteries should performed supervised personnel knowledgeable of batteries and required precautions. Keep unauthorized personnel away from the batteries. A battery can present a risk of electrical shock and high short-circuit current. The following precautions should be observed when working on batteries: •...
  • Page 6: Controls And Indicators

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk FRONT VIEW OF BATTERY BACK UP MAINS INDICATOR* (Green/Amber) POWER ON/OFF Alarm Silence* BATTERY FAULT INDICATOR* INDICATOR* (Green/Amber) (Red/Green) SHIPPING STANDBY BUTTON * MODE LED* (Concealed) (Red) * For details see controls and indicators section www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk...
  • Page 7 01926 463888 www.garagedoorsonline.co.uk REAR VIEW OF BATTERY BACK UP SYSTEM 350, 500 & 650 MODELS BLACK OUTPUT RECEPTACLES* ORANGE OUTPUT Do Not Use RECEPTACLES* (Battery Back Up and Surge Protection) INPUT CIRCUIT PROTECTOR MAINS/ POWER BATTERY COVER PLATE 1000 MODEL...
  • Page 8 www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk WHATS INCLUDED The P D Technology Power Series Unit is shipped with the following items. • P D Technology User Manual • Two 10A power cords, 2.0m (1 Output & Input and 1Mains Plug & Input) P D Technology Power Two 10Amp power cords (2.0 meters)
  • Page 9 www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk INSTALLATION This PDT Power Series is designed for all types of Roller Shutters. Maximum load must not exceed that shown on the Power Series rating label. Do not connect equipment that could overload the unit or draw half-wave current from it. Your total load earth leakage current must not exceed 3.5 mA.
  • Page 10 www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk CONTROLS AND INDICATORS ON/OFF/Alarm Silence Button This button controls output power to the connected load and has three functions: • • • Alarm Silence ON/OFF/ALARM Silence When the unit is off, pressing and releasing the main ON/OFF button will start the unit, and an audible alarm sounds briefly.
  • Page 11: Standby Indicator (Red)

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk Status Indicators: Mains, Battery, Fault, Standby There are four status indicators on the front of the unit (Mains, Battery, Fault and Standby), as shown in the diagram below. Each indicator illuminates to specify the status of the unit (see Troubleshooting section for details).
  • Page 12: Modes Of Operation

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk MODES OF OPERATION Normal Mode During normal mode operation, the PDT Power Series supplies conditioned power, to the connected equipment: mains power passes through the TVSS circuitry and the EMI/RFI filters and then through the Bi-Directional Converter to connected equipment. When the unit is in Normal mode, the Mains Indicator illuminates green.
  • Page 13: Battery Mode

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk Battery Mode The unit switches to battery mode in the event of an extreme voltage/frequency condition or complete mains failure. The battery system supplies power through the Bi-Directional Converter to generate power for connected equipment. When the unit is in Battery mode, the Battery Indicator illuminates green and an alarm sounds every 10 seconds.
  • Page 14: Standby Mode

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk Standby Mode Standby Indicator ON = Standby Mode When the mains power fails, the battery back up will go in to 24-hour standby mode. Within the first 24 hours of a power failure the unit can be woken up immediately with either a key switch or a key fob input.
  • Page 15: Dip Switch Modes

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk Dip Switch Modes VOLTAGE DIPSWITCHES - LOCATED ON BACK OF UNIT The unit is shipped out pre-set to 230 volts for operation. Under NO circumstances should the dip switches be adjusted whilst the unit is switched on. Please contact PDT before making any adjustment to this setting, as wrong voltage dip switch settings can seriously affect the safety features of the shutter when used with a RollerTec control system.
  • Page 16: Key Switch Inputs

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk Key Switch Inputs Volt free contacts on a key switch or other control device can be wired across terminal J3, which is, situated behind the PDT Power Series front cover. The contacts should be Normally Open, closing when the PDT Power Series is required. The unit will stay active for 25/45 seconds after the contacts are opened, or for as long as the contacts are closed up to a maximum time of 5 mins, at which point an auto shut down will occur.
  • Page 17: Battery Replacement Procedure

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk Battery Replacement Procedure Replacement requires removing the battery cover plate on the back or bottom of the unit. No tools are needed. To replace the batteries: 1. Remove the battery Figure 1 Figure 2 cover plate on the back/ bottom of the unit (Figure 1).
  • Page 18: Troubleshooting

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk TROUBLESHOOTING The information below indicates various symptoms a user may encounter in the event the PDT Power Series experiences a problem. Use this information to determine whether external factors caused the problem. See Troubleshooting Chart for suggested remedy. Mains Indicator 1.
  • Page 19: Troubleshooting Chart

    www.garagedoorsonline.co.uk 01926 463888 www.garagedoorsonline.co.uk Troubleshooting Chart If the unit fails to operate properly, turn off the unit and repeat the steps in the Installation section of this manual. If the problem persists, refer to the chart below: Problem Cause Solution Check the circuit protector on the rear of the unit.
  • Page 20: Technical Specifications

    A full technical support service is also available to any customers who require assistance with the installation or maintenance of the company's products. PD TECHNOLOGY ‘Controlling The Future ’ Registered in England & Wales No. 2524619 VAT No. 545 6413 41 ISO 9001: 2000 Certificate No.