- Turn the unit on by pressing the ON/OFF pushbutton once.
- Press the MODE button to cycle through the five mode selections:
COOL, FAN, HEAT, DRY, and AUTO Cool/Heat modes.
MODE - COOL
- Cycle mode pushbutton to highlight COOL.
- You may select HIGH, MED, LOW, or AUTO fan speeds by
pressing the fan pushbutton. It is recommended that you choose
Auto.
- The desired room temperature or set point is normally displayed
on the digital display. To adjust the set point, press the TEMP up or
down pushbuttons. The compressor will have a delayed start
(usually 3 minutes) before unit begins to cool. Note: Any
interruption to the power supply will result in a delayed
compressor start up.
- To display the actual room temperature press the SLEEP pushbutton
for 5 seconds and the room temperature will be displayed. After
releasing the SLEEP pushbutton the display will revert back to
displaying the set point temperature.
MODE – FAN
- For simply re-circulating air, choose the FAN mode. Choose any of the three fan speeds by pressing the FAN
pushbutton. Note: Temperature pushbuttons are invalid in FAN mode.
MODE - HEAT (model 1511 only)
- To heat, press MODE pushbutton to highlight HEAT.
- Select desired set point temperature by pressing TEMP up or down pushbuttons. It is recommended that the AUTO
fan speed be selected.
- After the delay, the compressor will start. Usually the fan will stop and will not re-energize until the heat
exchanger has warmed and then the fan will start to blow warm air.
- The unit will heat in the heat pump mode in ambient temperatures above approx. 45°F. The furnace will
automatically engage at ambient temperatures below approx. 45°F.
MODE - DRY
- The DRY mode can provide mild dehumidification for room temperatures above the set point and when
additional cooling is not required.
- Press MODE pushbutton to highlight DRY.
- Set the temperature to desired set point. Note: the fan speed is locked in LOW.
- The compressor will cycle on and off at approximate intervals of 6 minutes to extract moisture from the air.
- For humid room temperatures below the set point - a separate, specialty dehumidifier will be more effective.
- The unit can provide no dehumidification if the room temperature is below 64°F (18°C).
MODE – AUTO COOL/HEAT
-
This mode has an outdoor defrost mode (indicated by a flashing HEAT LED). During the outdoor defrost cycle, the
MODE pushbutton is inactive.
SLEEP FUNCTION
- With the unit operating in heat or cool mode, press sleep pushbutton to highlight the sleep light. The unit over the
next hour will automatically raise the set point by 2°F. Conversely in heat mode, the set point will be lowered 2°F.
TIMER FUNCTION
- The timer may be used to turn off the unit in the future (up to 24 hours) OR the timer may be used to turn on the unit
up to 24 hours in the future.
- Press TIMER pushbutton once and the display will flash. Within 3 seconds, press the timer pushbutton until you
have set desired time into the future to turn unit off. A subsequent press of the timer pushbutton will allow the time
to start the unit to be programmed.
LOCK FUNCTION (key symbol)
- This provides a means of locking in the mode and fan settings. To lock, press Temp Down pushbutton
simultaneously with MODE pushbutton. Hold for 3 seconds and the lock indicator will light. To unlock, repeat above
procedure.
AC IOM DUCTED 12/03/2014 rev 8

OPERATING INSTRUCTIONS

13
Wall mounted Thermostat control. An AC only model
(AC-1361) will not have the furnace pushbutton on the
wall pad unit.