Download Print this page

VMAXTANKS BC1225HD User Manual page 3

7 stage heavy duty fully automatic smart charger

Advertisement

the absorption stage was unable to fully charge the battery. The recondition mode will then begin to introduce a low constant current for a
period of 4 hours. The charger will then go into float charging mode.
This reconditioning stage can recover batteries from a deeply discharged state, increasing performance and battery life.
RECOND - This mode is used to recover deep discharged flooded batteries where you could expect a stratified acid (high acid weight in the
bottom, low on top). Check with battery manufacturer when in doubt. Use this mode with care, because the high voltage will cause some water
loss. 15.5V/31.0V is normally no problem for electronics in 12V/24V systems. Consult your supplier when in doubt. Life of the light bulbs will be
reduced at higher voltage. Try to disconnect light from the battery during this phase. Maximum effect and minimum risk for electronics is
achieved by charging a disconnected battery.
Float
After passing battery test, charger switches to float stage for a minimum of 1 hour insuring that the battery is at 100% state of charge. The
charger will then go into standby mode. If charger stays connected to battery, it will keep monitoring its terminal voltage. If the terminal
voltage drops below a lower limit, charger will automatically go back to the beginning of the charging curve.
5. Working conditions:
1. Charger should be placed in a well ventilated and dry area when in use. Avoid high temperature, dust and corrosive gases at all times.
2. Make sure the AC outlet matches that of the charger.
3. Free Charger vent from any blockages. Keep charger 2-3ft away from large objects. Clean filter as needed.
4. Altitude: below 10,000 feet.
5. Working temperature: -4 ºF — +140ºF.
6. Storage temperature: -49ºF — +140ºF.
7. Max humidity 90%,ambient temperature 77ºF.
6. How to Use:
1-
Connect positive charger clip (red) to the positive battery terminal, the negative charger clip (black) to the battery terminal.
2- Plug in AC power.
3- If Fault LED is ON, disconnect battery and check all connections.
4- Press the Power button to start charging. If Fault LED goes ON at this point, disconnect and check battery.
5- When all four LED's turn ON and Charging LED turns OFF, the battery is fully charged.
6- Press the Power button to turn off the AC power before disconnecting the battery.
7. Safety rules
Use in a well ventilated environment.
Avoid any flames, sparks and smoking when using charger.
Read instructions carefully before use.
Prohibit minors or unqualified users from operating charger.
Do not operate while exposed to rain or snow.
Turn off the AC power before connecting or disconnecting battery.
Do not use with non chargeable batteries.
Never attempt to short circuit the terminals.
Make sure charging outputs of this charger match charging specifications of rechargeable batteries in use.
Do not disassemble the charger; contact your supplier when service or repair is required. Incorrect reassembly may result in a risk of
electrical shock or fire.
VMAXTANKS™ BC1225HD & BC2413HD
www.vmaxtanks.com

Advertisement

loading

This manual is also suitable for:

Bc2413hd