Dear customer, Thank you for choosing our product. Read this manual carefully before installing your radiator, as it provides useful information for installation, ensure proper maintenance of the appliance. Remember that this manual must accompany the radiator should it be moved to a different installation location. THE PACKAGE INCLUDES: Aluminium radiator fitted with a thermostat with electronic regulation, kit made up of three mounting brackets and instruction manual.
CHARACTERISTICS 1.1. Characteristics of the appliance IP24 : appliance protected against splashing water Class II: double insulated 1.2. Technical characteristics of the electronic part Power supply 230V +/-10% AC 50 Hz Electrical resistor capacity 1000 W 1200 W 1500 W 1800 W Insulation class Class II...
WARNINGS A label on the side of the radiator contains the symbol shown here. The meaning of this symbol is: In order to avoid overheating the appliance, DO NOT COVER OR LAY any material or object over/on the radiator. IMPORTANT: in stand-by mode the electrical supply of the radiator is on and the - - - - display shows four segments: The radiator must never be:...
Page 5
Earthed. The cable contains: (BROWN: Live) (GREY/BLUE: Neutral) (BLACK: the Signal Wire). 1. INTELLI HEAT Ltd or any associated company or person cannot be held responsible for any fault, damage, or personal injury caused if these instructions have not been fully adhered to, or where non-original materials or accessories have been used.
INSTALLATION The radiator must not be installed in an alcove or beneath a power point or fuse spur. Curtains, furniture and objects which may obstruct proper heat distribution must be placed a minimum of 50 cm. from the front of the radiator. The radiator must be installed with a minimum distance of 120 mm between the floor and the lowest part of the radiator.
Install a multi-pole circuit breaker. The distance between the contacts must be at least 3 mm. AREA 1 2,5 m AREA 0 AREA 0 AREA 2 AREA 3 fig. 1 Please contact your INTELLI HEAT Representative for further assistance or information.
REGULATION AND PROGRAMMING 6.1. Turning the radiator on The appliance is regulated using four keys, as shown in the figure. When the appliance is in stand-by mode the display shows four segments. To turn the radiator on, press the ‘on/off’ key, as shown in the following figure: The radiator has various operating modes, as shown in the table on page 12.
Page 9
6.3. Programming Comfort temperature and Set back temperature It is possible to programme two separate temperature levels: Comfort temperature is the desired ambient temperature during operation in Comfort and Pilot Wire mode or when programming; Set back temperature is the ambient temperature in Night-time Reduction mode. These two temperature levels can be programmed using the plus and minus keys.
Page 10
PROGRAMME DAY PROGRAMME HOUR PROGRAMME MIN. You can now assign a programme to each day of the week. When a segment appears between two times on the programming bar (at the bottom of the screen), this indicates that the Comfort temperature level has been selected for this period. The absence of a segment indicates that during this period, the radiator will keep the temperature at the Set back temperature level.
Page 11
6.6. Description of operating modes 6.6.1. Programming mode In this mode, the ambient temperature remains at the TH or Set back temperature level, depending on the times set by the user. Comfort Setback 10 12 14 16 18 20 6.6.2. Pilot Wire mode (for radiators installed in France only) This mode enables the user to control the radiator from a remote location.
Summary of operating modes: Mode Description Programme: Daily and weekly programming which sets the two temperature levels (Comfort and Night-time) defined by the user for each time of day Pilot wire: The temperature depends on the Pilot Wire control (for radiators installed in France only) Stand-by: The receiver is in stand-by Comfort:...
TROUBLESHOOTING If the appliance stops working, do not use it: disconnect from the power supply and contact only a qualified technician who is authorized to work on this type of product. This appliance has been filled with an exact quantity of mineral oil. Repairs which require opening the liquid reservoir must be made by the manufacturer, its representatives or customer service.
DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY With the present, INTELLI HEAT Ltd Company Registration Number 05950029 Unit 18 Napier Place Stephenson Way, Thetford Norfolk IP24 3RL hereby declares that the ELECTRICAL RADIATORS FOR HEATING Model CALI Avanti are manufactured in accordance with European directives...
Page 16
Intelligent Heating Solutions INTELLI HEAT Ltd Company Registration Number 05950029 Unit 18 Napier Place Stephenson Way, Thetford Norfolk IP24 3RL www.intelligentheat.co.uk E: tech@intelligentheat.co.uk www.intelligentheat.co.uk/support IST 03 F 038-01 November 2012 (11/2012) 0ZLIBIST52...
Need help?
Do you have a question about the CALI Avanti and is the answer not in the manual?