SniffIT X1® User´s Guide
Specialist in leak testing &
leak detection since 1973
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SniffIT X1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nolek SniffIT X1

  • Page 1 SniffIT X1® User´s Guide Specialist in leak testing & leak detection since 1973 Page 1...
  • Page 2: Table Of Contents

    Assembling the SniffIT X1® ................... 4 ON/OFF ......................... 4 Locating a leak with helium or hydrogen ............. 4 Locating a leak with the SniffIT X1® ................... 5 Starting the operation ..................5 Locating the leak ....................5 Confirming the leak ....................5 Troubleshooting .......................
  • Page 3: The Sniffit X1

    The flexibility to detect both Helium and Hydrogen makes SniffIT X1® independent of the tracer gas used for leak detection, and is the only one of its kind.
  • Page 4: Preparing To Use Your Sniffit X1

    Preparing to use your SniffIT X1® Charging the Battery Before using the SniffIT X1® for the first time, fully charge the battery for 10 hours. Always try to charge the battery before using the instrument. The instrument’s battery is charged by placing the charger cord into the power jack at the bottom of the SniffIT X1®...
  • Page 5: Getting Started

    Getting Started Assembling the SniffIT X1® The SniffIT X1® is very easy to assemble. Take the SniffIT X1® out of the carrying case. Chose sniffer probe, and screw onto the front of the instrument. Filters are already assembled in each of the probe tops. The SniffIT X1® is now ready to be used.
  • Page 6: Locating A Leak With The Sniffit X1

    Auto-zero button while turning the nozzle approximately 1 meter away from the potential leak and SniffIT X1® will reset in less than one second. To confirm the leak, move the sniffer to the area where the sniffer indicated a leak earlier.
  • Page 7: Troubleshooting

    The SniffIT X1® cannot sniff fluids and will break if it gets wet. Avoid blowing compressed air into sniffer probe The SniffIT X1® will not work properly if compressed air is blown straight into the probe or the sniffer. Use only with clean helium and safe hydrogen mixtures The SniffIT X1®...
  • Page 8: Maintenance

    The user can easily maintain the SniffIT X1® by following these simple measures: 1. Cleaning the SniffIT X1®. Only use a damp cloth when cleaning. Never rinse the sniffer under water. Never use strong cleaning fluids when cleaning the sniffer.
  • Page 9: Limited Warranty

    TWO (2) YEARS from the date of original purchase. If a defect exists, at its option Nolek will (1) repair the product at no charge, using new or refurbished replacement...
  • Page 10: Technical Data

    AFFORDABLE: Least expensive sniffer on the If you need to charge your product with either helium or market. hydrogen before you use your SniffIT, please see the Nolek ChargeIT-series of instruments which is built for that exact purpose. Page 9...