Selection Of Installation Positions For Indoor Unit - Pridiom AWS090HR Installation And Repair Manual

High wall split ac
Hide thumbs Also See for AWS090HR:
Table of Contents

Advertisement

*Selection of installation positions for indoor unit*

* To be installed at the position where the air delivered from the unit can reach every corner of
the room;
* To avoid being affected by the outdoor air;
* To avoid blockage to the air inlet or outlet of the unit;
* To avoid too much oil smoke or steam;
* To avoid possible generation, inflow, lingering or leakage of flammable gases;
* To avoid high-frequency facilities (such as high frequency arc welders, etc.);
* To avoid the places where acid solutions are frequently used;
* To avoid the places where some special sprayers (sulfides) are frequently used.
* Not to install a fire alarming device near the air outlet of the unit (during operation, the fire alarm
device might be erroneously triggered by the warm air from the unit);
* Make sure of enough space for installation and maintenance.
* To take into consideration the operational convenience and safety in installation, it is recommended
to ensure enough space between the unit and the walls.
Left side: 150mm(6")
and above
* Height limits of indoor and outdoor units.
* Either the indoor unit or the outdoor unit can be higher, but the height difference must comply the stated
requirements.
* Try to reduce the bending of the piping line as much as possible so as to avoid possible negative impacts upon the
performances of the units.
Ceiling
Above 100mm(4")
Wall hanging plate
2300mm(7'6")
and above
ground
Indoor unit
5m(16'5")max.
outdoor
unit
1
INSTALLATION & REPAIR GUIDE
Split Wall-Mounted Air Conditioner
Right side: 150mm (6")
and above