To install a unit that uses R32 refrigerant, use dedicated tools and piping materials that
have been manufactured specifically for R32(R410A) use. Because the pressure of R32
refrigerant is approximately 1.6 times higher than R22, failure to use dedicated piping
material or improper installation can cause rupture or injury. Furthermore, it can cause
serious accidents such as water leakage, electric shock, or fire.
Do not use a vacuum pump or refrigerant recovery tools with a series motor, since it
may ignite.
2.2. Power
Always use a special branch circuit and install a special receptacle to supply power to
the room air conditioner.
Use a circuit breaker and receptacle matched to the capacity of the air conditioner.
Install a leakage circuit breaker in accordance with the related laws and regulations
and electric company standards.
The circuit breaker is installed in the permanent wiring. Always use a circuit that can
trip all the poles of the wiring and has an isolation distance of at least 3 mm between
the contacts of each pole.
The power source capacity must be the sum of the air conditioner current and the cur-
rent of other electrical appliances. When the current contracted capacity is insufficient,
change the contracted capacity.
When the voltage is low and the air conditioner is difficult to start, contact the power
company the voltage raised.
2.3. Electric requirement
Be sure to install a breaker of the specified capacity.
Regulation of cables and breaker differs from each locality, refer in accordance with local rules.
Voltage rating
Operating range
Cable
Conductor size [mm
model
1.5
07,09,12
Power supply
model
2.5
cable
18
model
4.0
22,24
model
1.5
07,09,12
Connection
cable
model
1.5-2.5
18,22,24
Demand
control signal
0.5-1.5
transmission
cable
*1
Selected sample: Select the correct cable type and size according to the country or
region's regulations.
Max. wire length: Set a length so that the voltage drop is less than 2%. Increase the
wire diameter when the wire length is long.
Breaker
Circuit breaker (over current)
Earth leakage breaker
*2
Select the appropriate breaker of the described specification according to the national
or regional standards.
*3
Select the breaker that enough load current can pass through it.
Before starting work check that power is not being supplied to all poles of the indoor
unit and outdoor unit.
Install all electrical works in accordance to the national standard.
Install the disconnect device with a contact gap of at least 3 mm in all poles nearby the
units. (Both indoor unit and outdoor unit)
• Install the circuit breaker nearby the units.
En-4
R32_outdoor_2版_01_EN.indd
4
WARNING
WARNING
CAUTION
CAUTION
1 ø 240 V (50 Hz)
198-264 V
2
]
*1
Type
Remarks
2cable + Earth
Type 60245 IEC57
(Ground),
1ø240V
3cable + Earth
Type 60245 IEC57
(Ground),
1ø240V
Double insulated
AS/NZS 5000.2.
(Max. length :
30m)
*2
Specification
model 07,09
Current : 10(A)
model 12,18
Current : 16(A)
model 22,24
Current : 20(A)
*3
Leakage current : 30mA 0.1sec or less
2.4. Pipe length
Pipe length
Maximum length
model 07,09,12,18KU
20m
*1
model 18
,22,24
30m
*1
Except 18KU
CAUTION
If the units are further apart than the maximum length of the piping is specified, correct
operation can not be guaranteed.
The outdoor unit with the refrigerant removed from the packaging is sealed.
(Indoor unit, the refrigerant is not sealed.)
2.5. Additional charge
For the additional amount, see the table below.
Pipe length
model 07,09,12,18KU
Additional refrigerant
*1
model 18
,22,24
Maximum amount of refrigerant charge
model 07,09,12
model 18KU
*1
model 18
,22,24
1470 g (1270 g + 200 g)
*1
Except 18KU
2.6. Operating range
Cooling mode
Dry mode
model 07,09,12,18KU
Outdoor temperature
*1
model 18
,22,24
*1
Except 18KU
2.7. Accessories
The following installation accessories are supplied.
Use them as required.
Drain pipe*
1
Drain cap*
1
*
2
1
*
1
: Included only reverse cycle model
*
2
: Included only model
18,22,24
One set of following parts are necessary installation of this product.
Name
Connection pipe assembly
Connection cable
Wall pipe
Decorative tape
Vinyl tape
Wall cap
Saddle
Drain hose
Tapping screws
Sealant

3. SELECTING THE MOUNTING POSITION

• Decide the mounting position with the customer as follows.
• Do not set to a place where there is oily smoke, oil is used in the factory, the unit can
contact sea breeze, sulfide gases will be generated in the hot spring area, corrosive
gases will be generated, animal may urine on the unit and ammonia will be generated
and a dusty place.
3.1. Outdoor unit
(1) If possible, do not install the unit where it will be exposed to direct sunlight.
(If necessary, Install a blind that does not interfere with the air flow.)
(2) Do not install the unit where a strong wind blows or where it is very dusty.
(3) Do not install in an area that has heat sources, vapors, or the risk of leakage or
accumulation of flammable gas.
(4) Do not install the unit where people pass.
(5) Take you neighbors into consideration so that they are not disturbed by air blowing
into their windows or by noise.
(6) Provide the space shown in figure so that the airflow is not blocked. Also for efficient
operation, leave open three of the four directions front, rear, and both sides.
(7) Install the unit where keep away more than 3 m from the antenna of TV set and Radio.
(8) Outdoor unit should be set to a place where both drainage and itself will not be
affected when heating.
Maximum height
(between indoor and outdoor)
15m
20m
20 m
25 m
30 m
Rate
None
-
-
-
None +100 g +200 g 20 g/m
850 g
1270 g
Heating mode
10 to 46 ˚C
-15 to 24 ˚C
-
10 to 46 ˚C
Cable tie
Installation
manual
3
1
1