Download Print this page

KitchenAid KUIA18NNJ Datasheet

Kitchenaid appliances ice maker specification sheet
Hide thumbs Also See for KUIA18NNJ:

Advertisement

Quick Links

PRODUCT MODEL NUMBERS
KUIA18NNJ
KUIS18NNT
KUIA18PNL
KUIC18PNT
KUIC18NNT
KUIS18PNT
Electrical: 115 volt, 60 Hz, AC only, 15 or 20
amp grounded circuit is required. A time-delay
fuse or circuit breaker and separate circuit is
recommended.
Water: A cold water supply with water pressure
of between 30 and 120 psi (207 and 827kPa) is
required to properly operate the ice maker.
Drain: Either a gravity drain system or a drain
pump system to carry water to an existing drain.
CABINET OPENING DIMENSIONS
34"
(86.4 cm)
Min.
34 "
(87.6 cm)
Max.
(8.9 cm)
24"
(60.1 cm)
DRAIN REQUIREMENTS
REAR VIEW
A. Drain hose (drain pump models only)
B. Vent hose (drain pump models only)
C. Water supply line
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
®

Ice Maker

14 "
(36.8 cm)
28 "
(72.4 cm)
9"
3
"
(22.9 cm)
18"
(45.7 cm)
SIDE VIEW
A
B
C
A. Recommended
location for electrical
and plumbing fixtures.
B. Floor level
A
B
⁷⁄₈
1
"
(1.9 cm)
1" (2.5 cm)
20" (50.80 cm)
2" - 1¹⁄₂"
(5 cm - 3.8 cm)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
PRODUCT DIMENSIONS
(85.9 cm)
Min.
(87.1 cm)
Max. with
leveling
legs fully
extended
"
(45.2 cm)
"
(65.1 cm)
"
(58.7 cm)
Drain lines must have a minimum of 5⁄8"
(15.88 mm) inside diameter.
Drain lines must have a 1" drop per 48" (2.54 cm
drop per 122 cm) of run or 1⁄4" drop per 12"
(6.35 mm per 30.48 cm) of run and must not have
low points where water can settle.
The floor drains must be large enough to
accommodate drainage from all drains.
The ideal installation has a standpipe with a 1-1⁄2"
(3.81 cm) to 2" (5.08 cm) PVC drain reducer installed
A
directly below the outlet of the drain tube as shown.
B
You must maintain a 1" (2.54 cm) air gap between the
drain hose and the standpipe.
It may be desirable to insulate the drain line
thoroughly up to the drain inlet.
C
A. Drain hose
B. 1" (2.54 cm) air gap
D
C. PVC drain reducer
D. Center of drain should be 20" (50.8 cm) from front of door,
with or without the
" (1.91 cm) panel on the door. The
drain should also be centered from left to right (8
from either side of the ice maker).
"
"
"
Ref. 2313820A
05-04-07

Advertisement

loading

This manual is also suitable for:

Kuia18pnlKuic18nntKuic18pntKuis18nntKuis18pnt