Dura Heat GFA50A User Instruction Manual

Dura Heat GFA50A User Instruction Manual

Propane construction heater
Hide thumbs Also See for GFA50A:

Advertisement

Quick Links

DURAHEAT_FA_SERIES-MANUAL_ENG_FNL:Layout 1
WARRANTY:
SERVICE AND LIMITED WARRANTY
GHP Group, Inc., warrants this product to be free from defects in materials and components
for one (1) year from the date of first purchase, provided that the product has been properly
installed, operated and maintained in accordance with all applicable instructions. To make a
claim under warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of
part(s) required to restore this heater to proper operating condition and an allowance for labor
when provided by a GHP Group, Inc., Authorized Service Center. Warranty part(s) MUST be
obtained through authorized dealers of this product and/or GHP Group, who will
provide original factory replacement parts. Failure to use original factory replacement parts
voids this warranty. The heater MUST be installed by a qualified installer in accordance with all
local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear
and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper
maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, trans-
portation and any and all such other costs related to repairing a defective heater will be the
responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE
SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER
EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WAR-
RANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU-
LAR PURPOSE TO ONE (1) YEAR FROM THE DATE OF FIRST
PURCHASE PRICE OF THE PRODUCT AND GHP GROUP INC., PRODUCTS SHALL NOT BE
LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or lim-
itation of incidental or consequential damages, so the above limitation on implied warranties, or
exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from
state to state.
Contact GHP Group, Inc., for consumer information, technical assistance and to obtain
replacement parts at 1-877-447-4768. You will need to provide the following information when
communicating with the help desk:
07/04/2009
4:55 PM
GFA40 / GFA50A / GFA100A / GFA150A
• Heater type and model number
• Serial Number
• Description of the part or problem
GHP Group, Inc., Skokie, IL 60076-4034
Phone: 1-877-447-4768
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GFA50A and is the answer not in the manual?

Questions and answers

Summary of Contents for Dura Heat GFA50A

  • Page 1 4:55 PM Page 1 WARRANTY: GFA40 / GFA50A / GFA100A / GFA150A SERVICE AND LIMITED WARRANTY GHP Group, Inc., warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
  • Page 2 PROPANE CONSTRUCTION HEATER USER’S INSTRUCTION MANUAL Duraheat MODELS: GFA40 (40,000 BTU/HR, FORCED - AIR) GFA50A (30,000/50,000 BTU/HR, FORCED - AIR) GFA100A (70,000/100,000 BTU/HR, FORCED - AIR) GFA150A (120,000/150,00 BTU/HR, FORCED - AIR) CSA 2.14a-2007, ANSI Z83.7a-2007 GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTION PROVIDED...
  • Page 3: Table Of Contents

    Illustrated Parts Breakdown GFA40 / GFA50A ......GFA40 / GFA50A ....10...
  • Page 4: Specifications

    4:55 PM Page 4 Dura Heat Propane Forced Air Construction Heaters The heater is designed and approved for use as a construction heater under ANSI Z83.7., CSA2.14 It is hard to anticipate every use which may be made of this heater.
  • Page 5: General Safety Instructions

    DURAHEAT_FA_SERIES-MANUAL_ENG_FNL:Layout 1 07/04/2009 4:55 PM Page 5 GENERAL SAFETY INSTRUCTIONS: Accidents are always tragic especially because so many of them could have been prevented with little care and judgment. There are some basic good practices, we hope you will follow for safe use of your heater.
  • Page 6 DURAHEAT_FA_SERIES-MANUAL_ENG_FNL:Layout 1 07/04/2009 4:55 PM Page 6 UNPACKING: 1. Remove heater from carton. 2. Remove all protective packing applied to heater for shipment. 3. Retain cartons and packaging material until unit is operated and found in good condition. 4. Check heater for any shipping damage. If heater shows any external or internal damage, promptly inform dealer/distributor where you purchased heater.
  • Page 7: Installation To The Propane Gas Tank

    DURAHEAT_FA_SERIES-MANUAL_ENG_FNL:Layout 1 07/04/2009 4:55 PM Page 7 INSTALLATION TO THE PROPANE GAS TANK: IMPORTANT: You must use a propane/LP gas supply cylinder that is compatible with the connec- tion device provided with the hose and regulator. 1. Provide propane/LP supply system (see Propane/LP Supply, page 4). 2.
  • Page 8: Lighting & Shutdown Instructions

    DURAHEAT_FA_SERIES-MANUAL_ENG_FNL:Layout 1 07/04/2009 4:55 PM Page 8 Propane is safe to use when properly handled. Careless handling of the Propane gas tank could result in fire and/or an explosion. Therefore: • Always keep tank/cylinder securely fastened in an upright position. •...
  • Page 9: Test Firing Heater & Storage

    DURAHEAT_FA_SERIES-MANUAL_ENG_FNL:Layout 1 07/04/2009 4:55 PM Page 9 SHUTDOWN INSTRUCTIONS: Shutoff Heater: WARNING: Motor and fan must be running before lighting, during operation and at shutdown, in order to prevent a flame-out condition which could result in personal injury or property damage. Turn gas valve knob clockwise to OFF position.
  • Page 10: Wiring Diagrams

    DURAHEAT_FA_SERIES-MANUAL_ENG_FNL:Layout 1 07/04/2009 4:55 PM Page 10 WIRING DIAGRAMS: CONTINOUS SPARK MODELS GFA100A/150A CONTINOUS SPARK MODELS GFA50A PIEZO/MANUAL SPARK MODELS GFA40 Page 8...
  • Page 11: Illustrated Parts Breakdown

    DURAHEAT_FA_SERIES-MANUAL_ENG_FNL:Layout 1 07/04/2009 4:55 PM Page 11 ILLUSTRATED PARTS BREAKDOWN PART NUMBER ITEM QTY. DESCRIPTION GFA40 GFA50A 2304818 2304818 SHELL IN ASSY 2001086/2001355 2001355 SCREW 2304829 2304942 NOZZLE 2304819 2304819 FRAME HOLDER 2001086/2001355 2001355 SCREW 2304826 2304826 THERMAL SWITCH BRACKET...
  • Page 12: Propane Construction Heater Illustrated

    DURAHEAT_FA_SERIES-MANUAL_ENG_FNL:Layout 1 07/04/2009 4:55 PM Page 12 PROPANE CONSTRUCTION HEATER ILLUSTRATED GFA40 / GFA50A Page 10...
  • Page 13: Illustrated Parts Breakdown

    DURAHEAT_FA_SERIES-MANUAL_ENG_FNL:Layout 1 07/04/2009 4:55 PM Page 13 ILLUSTRATED PARTS BREAKDOWN PART NUMBER ITEM QTY. DESCRIPTION GFA100A GFA150A 2304929 2304929 SHELL IN ASSY 2001355 2001355 SCREW 2304829 2304944 NOZZLE 2304930 2304931 FRAME HOLDER 2001355 2001355 SCREW 2304826 2304826 THERMAL SWITCH BRACKET 2201373 2201563 THERMAL SWITCH...
  • Page 14: Propane Construction Heater Illustrated

    DURAHEAT_FA_SERIES-MANUAL_ENG_FNL:Layout 1 07/04/2009 4:55 PM Page 14 PROPANE CONSTRUCTION HEATER ILLUSTRATED GFA100A / GFA150A Page 12...

This manual is also suitable for:

Gfa150aGfa100aGfa40

Table of Contents