Adding Water.

An added feature of this model.
Humidity absorbed from the air condenses at the Evaporator, turns into water and is collected in the
internal tank. When enough water is collected it is pumped up and over the condenser, assisting the
cooling of the refrigerated gas, increasing the COOLING CAPACITY. Some of this recycled water is
evaporated at condenser and expelled from the machine as water vapor though the exhaust hose.
To utilise the full potential of your air conditioner from initial start up we recommend that 1500 mls of
water be added to the internal water tank via the small draw located at the rear bottom center of the
machine.
Normally an adequate quantity of water is collected to keep the recycling process operating.
During very humid conditions the collection of water may over take the evaporation rate and the
internal tank may become full.
The maximum water level in the tank is controlled by a float and micro switch, when the preset level
is exceeded the Water Full Indicator will light and the compressor will shut off automatically, the fan
motor will stay circulating the air. A buzzer will sound every 5 minutes until the water is drained.
At this time, you must empty the water tank as described " Water Drainage".
When the ambient temperature reaches 38º or greater while the Compressor is running and there is
no water in the internal tank the Water Injection Indicator will flash. This indicates that you should add
water, after filling the indicator goes off.
When the ambient temperature is lower than 38º while the compressor has been running over an
hour and there is no water in the internal tank the Water Injection Indicator will flash. This again
indicates that you should add water, after filling the indicator goes off.