2. Changing the set time.
When Timer is on, you can check remnant time by pressing Timer button. It will flash 5 times. Press
Up or Down button to adjust set time. The set time can also be cancelled if you press the Timer
button once again during the flashing time.
3. Set timer-on.
Press the Timer button when the unit is off. Same as timer-off set. Once the preset time has passed
the unit will turn on automatically.
Cooling Operation.
Press Mode button
Press Up or Down
The range is 18 ~30, the setting will increase or decrease each time a button is pressed. The
selected value will remain showing on the LCD.
Please Note - The temperature adjustment setting is not a direct correlation to the ambient
room temperature. For example adjusting the setting to 18 will not necessary bring the
ambient room temperature down to 18º
Press Fan Speed button on the Control panel or
required fan speed.
Press Swing button
Adjust horizontal louver by hand.

Dehumidifying Operation.

NOTE! The machine operates in the cooling mode but it does not lower the room temperature. It
absorbs the excessive humidity present in the air.
Remove the exhaust tube from the air-conditioner or direct the outlet back into the room.
Press Mode button or
automatically selected to Low.
LED displays ambient room temperature. Fan speed and temperature cannot be adjusted.
When the water tank is full, the Water Full Indicator will illuminate and the compressor will shut off
automatically, the fan will stay on circulating the air. At this time, you must empty the water tank as
described in the Drainage section.

Continuous Drainage.

In very humid conditions to avoid the unit from shutting down when the water tank is full the unit can
also be continuously drained if a convenient drainage position is available.
A longer PVC tube can be used to extend the drainage outlet.
Important!
The water is only gravity drained therefore the tube must lay lower and drain at a lower level than the
outlet tube at the rear of the air conditioner.
on Remote Control or
to adjust temperature cooler or warmer.
on Control Panel or Remote to adjust the direction of the vertical louver.
on the Remote to choose Dehumidifying mode. The fan speed is
on Control Panel to select Cool mode.
on the Remote Control to set the