Figure 1: Location of blue LED, and red LED on TS0870x- series Smart Card Readers. The TS0870, TS0870H (heavy duty), and TS0870D (decorative) Smart Card Readers are multifunction, all-purpose proximity card readers suitable for most locations requiring a short-range reader. Product features include: •...
Before you begin Before you can successfully install the reader you need to know some details about the system, depending on whether the reader is to be normally used in on-line or off-line mode. These modes are described in the following sections.
An external open collector output (violet wire) may be configured as a tamper control for offline mode. For TS0870x readers with firmware version V07 or later, the watch dog option may be used to monitor the tamper for offline mode. Wiegand watch dog data is transmitted when the tamper is sealed. See option 7—Watch Dog on page 12 for details.
Figure 2: LAN power, data, and earthing connections to Alliance or Challenger panel from a single reader (a number of readers would typically be connected to the control panel). Figure 3: LAN connection to Intelligent 4-Door or 4-Lift Controller Wiegand or magnetic stripe connection Figure 4: ’Off-line’...
Challenger V8 — use the first relay number of the relay control group assigned to the reader. Alliance — use the first output number of the output controller assigned to the reader. Figure 6: Door relay and simple push button connections TS0870x-series Installation & Programming Guide 4.0...
Use an LCD RAS to program the required address (except for a reader that’s supposed to be at address 16). You can also change other reader programming from the factory defaults at this time. Refer to Reader programming on page 12 for details about the programming options that apply to the TS0870x-series Smart Card Readers.
TS0870P Smart Card Programmer. Refer to the management software on-line help for details of how to program the reader configuration card. Refer to Reader programming on page 12 for details about the programming options that apply to the TS0870x- series Smart Card Readers.
TS0870P Smart Card Programmer. Refer to the management software on-line help for details of how to program the reader configuration card. Refer to Reader programming on page 12 for details about the programming options that apply to the TS0870x- series Smart Card Readers.
Offline mode only. If enabled, data is sent to the host every one minute to indicate that the RAS is connected and operating normally. The tamper must be sealed for watch dog messages to be transmitted. TS0870x-series Installation & Programming Guide 4.0...
Page 13
(Open Collector Output) • Door relay (online mode only) — The open collector output activates (active low) when the door open signal is received by the TS0870x. • Tamper (online or offline modes) — The open collector output activates (active low) when the tamper is unsealed (if enabled in option 17—Tamper Options).
Page 14
If disabled, this option cannot be re-enabled using a configuration card. It may only be re-enabled by the following means: • Using menu option 17—Tamper Options. • Using menu option 11—Factory Defaults. • By badging a default configuration card on the reader. TS0870x-series Installation & Programming Guide 4.0...
Programming credit options TS0870x-series Smart Card Readers can be set-up to respond to badging by operating relay-activated devices such as photocopiers, drink dispensers, etc., instead of being used for access purposes. To do so, the Smart Card must be programmed with the correct access level, credits, and location, in order to activate the relay output.
Wiegand protocol, the full 32 bit card ID protocol, the full 32 bit card ID number is number is transmitted. transmitted. TS0870x-series Installation & Programming Guide 4.0...
Statements N4131 When installed as directed, this product conforms to the standards set by Standards Australia on behalf of the Australian Communications Authority (ACA). Disclaimer The customer is responsible for testing and determining the suitability of this product for specific applications. In no event is GE Infrastructure Security Pty Limited responsible or liable for any damages incurred by the buyer or any third party arising from its use, or their inability to use the product.