Component
13. Outlet Thermostat
(Auto reset)
• Check Top Marking :
N95
13. Outlet Thermostat
(Manual reset)
• Check Top Marking :
N100
Test Procedure
Measure resistance of terminal
to terminal
Open at 203 ± 7°F (95 ± 5°C)
Close at 158 ± 9°F (70 ± 5°C)
Measure resistance of terminal
to terminal
Open at 212 ± 12°F
(100 ± 7°C)
Manual reset
Check result
Resistance value
Continuity < 1Ω
If thermal fuse is open must
be replaced
Resistance value
Continuity < 1Ω
15
Remark