Download Print this page

Kappa ECMR-250 User Manual

Dimmer module receiver

Advertisement

Quick Links

USER MANUAL

MODEL: ECMR-250
Dimmer module receiver
FEATURE:
Self program, 67 million codes.
ON/OFF/DIMMER function.
Suitable only for lights, 230V incandescent or halogen
lamp.
Connect with (non-dimmable) electronic transformer for 12V halogen lamp.
Not suitable for traditional transformer.
6 memories for scene setting.
Green LED indication.
Compatible to all KAPPA transmitters.
Standby power consumption: 1 W.
INSTALLATION: (Fig. 1)
- Disconnect main power line.
- Connect LIVE AC 230V wire to ECMR-250 port L↓
- Connect LIVE lamp wire to ECMR-
- Connect Neutral AC 230V wire to lamp.
- Turn on main power line.
- LED indicator light on and load light on.
HOW TO SET / DELETE CODE WITH KAPPA
TRANSMITTER:
SET (LEARN) CODE: (Fig. 2)
-
After correct installation, switch on the main power.
-
Bring the transmitter near the receiver, push the self
program button on receiver once.
-
Receiver LED will blink slowly, press transmitter
selected "ON" button.
-
Receiver connected lamp will blink twice, code is
confirmed and LED stops blinking.
(Remember the transmitter button you selected for
the programmed receiver.)
-
Transmitter and receiver code is auto programmed.
-
Same procedure to link with KAPPA code switch
transmitter.
250 port

Advertisement

loading

Summary of Contents for Kappa ECMR-250

  • Page 1: User Manual

    Standby power consumption: 1 W. INSTALLATION: (Fig. 1) - Disconnect main power line. - Connect LIVE AC 230V wire to ECMR-250 port L↓ - Connect LIVE lamp wire to ECMR- 250 port - Connect Neutral AC 230V wire to lamp.
  • Page 2 “ON” button again to stop dimming. ** If not manual to stop dimming, after light running up/down 4 cycles, ECMR-250 will automatically stops dimming at last selected brightness level. ** Next time lamp switched on will stay at last brightness level before switching off.
  • Page 3 1. When connecting with (non-dimmable) electronic transformer for low voltage 12V halogen lamp, to calculate load, add the VA ratings of the transformers (not the wattage of the lamps). At this moment, the load for ECMR-250 means this electronic transformer (VA) not the lamp. (Fig. 6)
  • Page 4 -Do not use with fluorescent or compact fluorescent lamps (CFL); -Do not use with traditional transformers (conventional, wire-wound or toroidal transformers); -Do not use with electric motors. -Wrong application of traditional transformers (conventional, wire-wound or toroidal transformers) will cause ECMR-250 out of function. (eg. Fig. 7)