Lenovo ThinkCentre 9120 Hardware Maintenance Manual page 65

Hide thumbs Also See for ThinkCentre 9120:
Table of Contents

Advertisement

Diagnostic Error Code
001-032-XXX
System Device Controller failure
001-034-XXX
System Device Buffer Allocation failure
001-035-XXX
System Device Reset condition detected
001-036-XXX
System Register error
001-038-XXX
System Extension failure
001-039-XXX
System DMI data structure error
001-040-XXX
System IRQ failure
001-041-XXX
System DMA failure
001-195-XXX
System Test aborted by user
001-196-XXX
System test halt, error threshold exceeded
001-197-XXX
System test warning
001-198-XXX
System test aborted
001-199-XXX
System test failed, cause unknown
001-250-XXX
System ECC error
FRU/Action
System board
1. Reboot the system
2. Flash the system. See "Flash update
procedures" on page 335
3. Run memory test
4. System board
System board
System board
1. Adapter card
2. System board
1. Flash the system. See "Flash update
procedures" on page 335
2. System board
1. Power-off/on system and re-test
2. System board
1. Power-off/on system and re-test
2. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Flash the system and retest. See "Flash
update procedures" on page 335
3. Go to "Undetermined problems" on page
82
1. Go to "Undetermined problems" on page
82
2. Flash the system and re-test
3. Replace component under function test
System board
Chapter 7. Symptom-to-FRU Index