Connecting Cables To The Sc720/Sc820; Figure 2: Sc720/Sc820 Rear Panel; Table 4: Sc720/Sc820 Rear Panel Connectors - Bosch Safecom SC720 Operation And Installation Manual

Data repeater
Table of Contents

Advertisement

SC720/SC820
Installation
3.2

Connecting Cables to the SC720/SC820

The following connectors are located on the rear panel (See Figure 2).
Item
Name
1
ACCESSORY
2
TX
3
RX
4
AC POWER
5
DC POWER
This COMPLETES the installation procedures for the SC720/SC820 Data Repeater.
90007-201C
TX
RX

Figure 2: SC720/SC820 Rear Panel

Description
The Accessory connector is NOT currently utilized for Data Repeater operations.
Available for future expansion capability.
The ONLY item that should be connected to the Accessory
connector is the Senses supplied Molex plug. Otherwise,
equipment damage may occur.
Connect the feedline cable which will be routed TO the transmitting antenna, the
XMTR input port of a duplexer, or the input to a transmitter combiner.
Connect the feedline cable which will be routed FROM the receiving antenna,
the RCVR output port of a duplexer, or the output port of a receiving distribution
panel.
Connect the AC power cord to a 120 VAC/60 Hz grounded duplex electrical
outlet.
Ensure the power cord is secured to the duplex electrical outlet
utilizing a plug retaining clamp. This will prevent inadvertent
AC power loss due to accidental disconnection from the
electrical outlet.
Connect the 12 VDC line from the DC power source.

Table 4: SC720/SC820 Rear Panel Connectors