IMPORTANT: Owner please fill out and mail warranty card supplied with heater.
This is an unvented gas fired heater. It uses
air (oxygen) from the room in which it is
installed. Provisions for adequate combustion
and ventilation air must be provided. Refer to
the section titled "Combustion and ventilation
air requirement".
Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies.
Children and adults should be alerted to the hazard of
high surface temperature and should be kept away to
avoid burns or clothing ignition.
Young children should be carefully supervised when they
are in the same room with the appliance.
Do not place clothing or other flammable material on or
near the appliance.
Installation and repair should be done by a qualified
service person.
The appliance should be inspected before use and at
least annually by a qualified service person.
frequent cleaning may be required due to excessive lint
from carpeting, bedding material, etc. It is imperative
that control compartments, burners, and circulating air
passageways of the appliance be kept clean.
W A R N I N G
INSTALLATION
AND
OWNER'S GUIDE
Effective Date: September 2011
GENERAL INFORMATION
This series is design certified by the CSA Laboratories as an
Unvented Heater, and must be installed according to these
instructions.
This appliance is intended for supplemental heating.
This appliance may be installed in an aftermarket
permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
WARNING:
manual is not followed exactly a fire or
explosion
damage, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any telephone in your building.
Immediately call your gas supplier from a
neighbor's telephone.
supplier's instructions.
If you cannot reach your gas supplier, call the
fire department.
More
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Any change to this heater or its controls can be dangerous.
For proper ventilation, provide a minimum fresh air opening of one square
inch for every 1,000 BTU's of gas burner capacity.
VENT-FREE
ROOM HEATER
Models: SC10M-1–NG/LP
If the information in this
may
result
causing
WHAT TO DO IF YOU SMELL GAS
property
Follow the gas
FORM 43126250
Sept 2011

Advertisement

loading
Need help?

Need help?

Do you have a question about the SC10M-1-NG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SunStar SC10M-1-NG

  • Page 1 INSTALLATION VENT-FREE OWNER'S GUIDE ROOM HEATER Models: SC10M-1–NG/LP Effective Date: September 2011 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. IMPORTANT: Owner please fill out and mail warranty card supplied with heater. GENERAL INFORMATION This series is design certified by the CSA Laboratories as an Unvented Heater, and must be installed according to these instructions.
  • Page 2 W A R N I N G S ANY ALTERATION TO THE ORIGINAL DESIGN, INSTALLED OTHER THAN AS SHOWN IN THESE INSTRUCTIONS, OR USED WITH A TYPE OF GAS NOT SHOWN ON THE RATING PLATE IS PROHIBITED AND VOIDS THE WARRANTY. The installation must conform to local codes.
  • Page 3 heater must be a minimum of 18" above the indoor combustion air is provided by the finished floor. method described in the National Fuel Gas 16. A vent-free gas heater will increase the Code, ANSI Z223.1/NFPA amount of humidity in the room in which it International Fuel Gas Code, or applicable is installed.
  • Page 4 COMBUSTION AND VENTILATION AIR REQUIREMENT WORKSHEET The purpose of this worksheet is to help you determine if you are planning to install this heater in an “unconfined” or a “confined” space. An “unconfined” space is one that is large enough to meet all the combustion and ventilation air requirements of all the fuel burning appliances to be in operation in this space.
  • Page 5: Safety Information For Users Of Lp-Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas that can cause fires Someday when there may not be a minute to lose, and explosions. In its natural state, propane is odorless everyone's safety will depend on knowing exactly what to and colorless.
  • Page 6: Specifications

    SPECIFICATIONS Model SC10M-1-NG Model SC10M-1-LP BTU/HR Input 9,500 8,500 Type Gas Natural Gas LP Gas Ignition Type Piezo ignitor Piezo ignitor Temp. Control Manual Manual Weight Heater 12 lb. 12 lb. Shipping 13 lb. 13 lb. Inlet Gas Pressure Maximum 14.0"...
  • Page 7 WALL MOUNT INSTALLATION IMPORTANT: Before installing this heater, make sure that a wall stud is located in the center of the unit. This wall stud will give better support to the unit. See the following instructions to place the "C" angle to the wall stud: Select the elbow position as indicated in Figure 2-1.
  • Page 8 INSTALLATION TO GAS SUPPLY The gas supply must comply with local codes, or in their absence, the installation must be in accordance with the American National Standard (National Fuel Gas Code) NFPA 54, also known as ANSI Z223.1 - latest edition, available from the ANSI, Inc., 1434 Broadway, New York, New York 10018, or the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
  • Page 9 If you need to replace the burner assembly, loosen screws A and holds the metal strip onto the pilot assembly. Remove the B, unscrew the tubing fittings C, and disconnect the assembly, cover and blow any dust out. Reassemble and check for see Figure 5 .
  • Page 10 1. STOP! Read the safety instructions mentioned above. 6. Continue depressing control knob for 30 seconds after pilot is lit before releasing. 2. Make sure manual shutoff valve is fully open. If knob does not pop up when released,stop and inmediately call your service technician or gas 3.
  • Page 11: Troubleshooting

    TROUBLESHOOTING TROUBLE CAUSE SOLUTION PILOT TROUBLE  Not pushing piezo all the way down until "click"  Review Lighting Instructions  Lead wire loose at piezo igniter  Tighten connection  Lead wire loose at electrode  Tighten connection  Lead wire broken ...
  • Page 12 WARNING: This heater must be installed on a wall whenever it is installed in a bedroom. The optional floor stand is available from Sunstar Heating Products Inc. or through your dealer. -11-...
  • Page 13 REPAIR PARTS LIST MODELS: SC10M-1-LP (Propane Gas) SC10M-1-NG (Natural Gas) WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
  • Page 14 REPAIR PARTS LIST - CONTINUED MODELS: SC10M-1-LP (Propane Gas) SC10M-1-NG (Natural Gas) WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
  • Page 15: Repair Parts

    HOW TO ORDER REPAIR PARTS … All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the nameplate on your equipment. Next, determine the Part Number (not the Index Number) and the Description of each part from the following appropriate illustration and list. Be sure to give all this information.
  • Page 16 Manufactured for: SUNSTAR HEATING PRODUCTS, INC. 306 West Tremont Avenue Charlotte, NC 28203-4946 (704) 372-3486...

This manual is also suitable for: