Filling The Chassis·mounted Lpgas Tank; Lp Gas System Leak Checks - Fleetwood Southwind 1979 Owner's Manual

Table of Contents

Advertisement

:.;~7f~~if~~::-
. -
d
'.I
~-<24
:' - water from entering the. regulator which will cause it to
.::
freez~
again, If ,the problem persists, ask your LP gas
supplier to service the tank or regulator, removing the
, mOisture Qr adding an ice·inhibitor as required,
..... - -.... - - - -.... - -........ - -..................
FILLING THE CHASSIS·MOUNTED LP GAS TANK
CAUTiON
i
If you have a chassis.mqunted storage tank, drive the
DO NOT USE PLIERS OR A WRENCH TO TIGHTEN
.'.
vehicle to an LP gas supplier or one of the service sta. VALVES, IF A VALVE IS NOT LEAK·TIGHT WHEN
tions which sell LP gas to have the tank filled. Look un' CLOSED BY HAND, SEE YOUR LP GAS SERVICE
der ~~s, Li,quified Petroleum, Bottled .and Bulk, in your
L ..
R .. E .. P .. R .. E .. S .. E .. N .. T;.;A.;.T.;.IV.;.;;;.E.;.... _ _ _ ... _ .... _ _ _ _
-.J
classified directory or refer to the service directory avai·
able at your dealer, For additional information refer to
instructions fdr your gas appliances provided'in your
r-------~~~~'!!!""--
... ----. . .
owner's k i t . '
WARNING
LP GAS SYSTEM LEAK CHECKS
NEVER CHECK FOR LEAKS WITH
AN OPEN
~or
your safety,
~heck
for leaks in your gas system each FLAME, DO NOT CHECK COPPER PLUMBING
time the tank IS filled or before each trip. Always check LINES FOR'LEAKS USING AMMONIATED HOUSE·
the system any time the odor of garlic is detected. To HOLD·TYPE DETERGENTS BECAUSE THESE CAN
perform a leak check,open the tank valve and spread a CAUSE CRACKS TO FORM ON THE LINE AND
non.~mmoniated
type (i'e. castile, etc,) soap.bubble BRASS FITTINGS. IF THE LEAK CANNOT BE LO·
S?1.utlon over all connections. Escaping gas will create CATED, TAKE THE UNIT TO AN LP GAS SERVICE
vIsible bubbles to show the location of any leak.
REPRESENTATIVE,
!<eep the,
t~nk
valve closed and turn OF F all appliances
If .the Unit IS not being used. When operating LP gas ap·
pllances, use only one tank at a time to avoid depleting
your LP gas supply.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents