3-1. Judging Method When Image Does Not Appear
3-1-1. Flow chart
a) When the STBY LED is flashing.
Trouble mode is judged by the following flashing times.
1
2
0.3 0.3
0.3 0.3
b) When the STBY LED flashing is not lighted.
The power supply circuit is defective.
PFM-42B2/42B2E
Section 3
Trouble Shooting
Picture does not appear
Check the indication on the indicator
in the lower right of the front panel. (STAND BY)
2 times
3 times
4 times
5 times
3
6
1
3
X SUS
TEMP (DD CON)
Y SUS
TEMP (I/O Block)
Center
TEMP
Digital
5V
6 times
PANEL
FAIL (PDP)
2
3-1