Sony PFM-42B2 Service Manual page 27

Flat panel monitor
Hide thumbs Also See for PFM-42B2:
Table of Contents

Advertisement

c) AUTO PLL PIXEL
Selects the functions that are automatically adjusted
when PIXEL ADJUST is executed.
ON
: Both the TOTAL H PIXEL and DOT PHASE
are automatically adjusted.
OFF
: Only the DOT PHASE is automatically
adjusted.
In the case that the PFM-42B2/B2E is used under the
environment where input signal contains much noise,
there are cases that the PIXEL ADJUST mis-opera-
tions. Therefore, set the AUTO PLL PIXEL to the
OFF position. In such a case, the TOTAL H PIXEL
can be adjusted only manually.
This function becomes valid only when the signal that
enables the PIXEL ADJUST is inputted to the PFM-
42B2/B2E.
Set the AUTO PLL PIXEL item to the ON position
normally.
d) H/V SHIFT
Selects the method to control the horizontal and
vertical picture shift.
EDGE : When EDGE is selected, a picture is shifted
by changing the starting position when
reading data into memory. Using this
function, the entire area including blanking of
all pictures can be displayed by shifting. The
variable range of shifting is 1 horizontal and
vertical period respectively.
CAPT : When CAPT is selected, the picture that is
already written into memory is shifted by a
scan converter. Using this function, a picture
can be shifted as much as ± 50 % of a
picture. When a picture is partly lacked at an
end of a picture, the lacked portion of a
picture cannot be displayed.
Set the H/V SHIFT item to the EDGE position normal-
ly.
PFM-42B2/42B2E
e) VIDEO SHARP SW
Sets analog aperture ON or OFF.
The two methods are used for the aperture correction
of the video signals (NTSC/PAL/SECAM/NTSC4.43/
PAL60/PAL-M and YUV signal having horizontal
frequency of 15 kHz). These two methods are the
scaling filter and the analog aperture of the scan
converter.
ON
: Both the scaling filter and the analog aperture
of the scan converter are used for aperture
correction.
OFF
: Only the scaling of the scan converter is used
for aperture correction.
This function becomes valid only when the signal
(NTSC/PAL/SECAM/NTSC4.43/PAL60/PAL-M and
YUV signal having horizontal frequency of 15 kHz) is
inputted to the PFM-42B2/B2E.
Set the VIDEO SHARP SW item to the ON position
normally.
f) AUTO FT CANCEL
Sets the FT (field tearing) cancel circuit ON or OFF.
The PFM-42B2/B2E has the FT (field tearing) preven-
tion circuit caused by the overrun of memory while it
is displaying the moving picture (video and DTV).
However, there can be cases that noise appears on
screen when the FT (field tearing) prevention is being
executed.
ON
: The FT (field tearing) is cancelled in every
picture size and in every shift conditions as
long as the PFM-42B2/B2E is receiving the
moving picture. When this item is set to ON,
noise may appear only once after the size/
shift is adjusted. (Noise does not last long
but appears only once when the size/shift
adjustment is complete.)
OFF
: The FT (field tearing) cancel circuit is
disabled. When OFF is selected, there can be
a case that the FT (field tearing) appears on
screen depending on the adjustment condi-
tions of picture size/shift. However, the noise
due to operation of the processing circuit
does not occur.
Set the AUTO FT CANCEL item to the ON position
normally.
2-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rm-42bBkm-b12Pfm-42b2eBkm-b10Bkm-b13

Table of Contents