Communication Error - LG LM-1830C2L Service Manual

Multi type room air conditioner
Hide thumbs Also See for LM-1830C2L:
Table of Contents

Advertisement

7. Outdoor unit does not operate at all.
Items
• Power Transformer
(Outdoor unit)
- Input Voltage
- Output Voltage
• IC01D(7812) Output
(Indoor/Outdoor unit)
• IC02D(7805) Output
(Indoor/Outdoor unit)
• IC01A(KIA7036, Reset IC)
X01(8MHz)
• Check the electrical wiring diagram of outdoor side.
• Check the abnormal condition for the component of
• Check the "open" or "short" of connecting wires between indoor and

8. Communication error

• The control data can be transmitted or received between indoor and outdoor unit with one signal cable.
• If the data be disturbed by any noise level and misconnection, the unit will be operated incorrectly. In this
case, the indoor unit blinks the operation and operation LED on display and indoor fan, outdoor fan, COMP
are not operated.
• The unit can be reoperated by On/Off control of Remocon.
Check Outdoor Unit
PCB Board Operation Check in Outdoor
- About AC220V/240V ± 10% - Check the power voltage
- About AC14 ± 3V
• DC + 12V
• DC + 5V
Turn off Main Power
Compressor/Outdoor Fan Motor/4-way.
outdoor.
Content
-51-
Remedy
• Replace Trans
• Replace IC01D
• Replace IC02D
• Replace faulty parts

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents