Carrier 50VL-A Performance Installation Instructions Manual page 16

14 seer single-packaged air conditioner system with puron (r-410a) refrigerant single and three phase 2 - 5 nominal tons (sizes 24 - 60)
Table of Contents

Advertisement

DANGER: ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING
FIELD
SUPPLY
POWER
L1
UNIT ONLY
MAXIMUM WIRE
SIZE 2 AWG.
EQUIP_GND
FOR WIRING WITH
1 2
ELECTRIC HEATERS
SEE SCHEMATIC
ON HEATER
1 1
ACCESSORY.
N 1
SEE NOTE
7
TSTAT
RED
R
BRN
C
Y
YEL
GRN
G
DH
BLU
W2
WHT
VIO
W3
UNIT COMPONENT ARRANGEMENT
OUTDOOR FAN
OFM
SECTION
COMPRESSOR
INDOOR FAN
SECTION
SECTION
LPS
HPS
IFM
CAP
HC F
COMP
C
S
CCH
R
CONNECTION WIRING DIAGRAM
IF USED
CCH
BLK
GRN
BLK
BLK
C
1
11
21
BLK
L2
YEL
23
23
1
YEL
BLK
230
200
TRAN
24V
SEE NOTE
IFB
CONTROL BOX AREA
23
21
C
23
11
SINGLE PT.
CONNECTION
FOR
ELECT.HEAT
TRAN
IFB
EQUIP.
GND
SEE HEATER
SCHEMATIC
FOR WIRING
DISCONNECT
PER NEC
24V SPLICE
24V POWER ENTRY
BOX
Fig. 12 - - Connection Wiring Diagram 208/230- -1- -60
BLK
BLK
YEL
YEL
YEL
CAP
BRN
H
C
F
YEL
YEL
BLU
BLK
L2
GND
GRN-YEL
GND
L1
COM
COM
GRN/YEL
BRN
C
SEE NOTE 5
BRN
BRN
RED
8
ACCESSSORY ELECTRIC HEAT
WHT
WHT
1
VIO
VIO
1
HR1,2,3
PNK
PNK
1
HR1 & 2 (10 KW)
GRY
GRY
1
HR1,2
BRN
BRN
1
HPS
BLK
BLU
BLU
BLK
LEGEND
FIELD SPLICE
TERMINAL (MARKED)
TERMINAL (UNMARKED)
SPLICE (IF USED)
SPLICE (MARKED)
FACTORY WIRING
FIELD CONTROL WIRING
FIELD POWER WIRING
ACCESSORY OR OPTIONAL
WIRING
TO INDICATE COMMON
POTENTIAL ONLY:
NOT TO REPRESENT WIRING
16
SCHEMATIC
230-1-60
OFM
BRN
COMPRESSOR PLUG
C
COMP
R
S
IFM
1
2
3
4
5
& 6
SEE NOTE
4
HR1 (5 KW)
BRN
HR1
BRN
1
3
BRN
HR4
1
3
& 4 (20 KW)
HR2
BRN
BRN
HR3
& 3 (15 KW)
LPS
BLU
C1
C
C2
C
CONTACTOR
CAP
CAPACITOR
ENERGIZED
CCH
CRANK CASE HEATER
COMP COMPRESSOR MOTOR
DEHUM DEHUMIDIFICATION MODE
GND
GROUND
HPS
HIGH PRESSURE SWITCH
HR
HEATER RELAY
IFB
INTERFACE FAN BOARD
IFM
INDOOR FAN MOTOR
LPS
LOW PRESSURE SWITCH
OFM
OUTDOOR FAN MOTOR
STD
STANDARD
TRAN TRANSFORMER
NOTES:
1. IF ANY OF THE ORIGINAL WIRES FURNISHED ARE REPLACED,
IT MUST BE REPLACED WITH TYPE 90 DEGREE C WIRE OR
IT'S EQUIVALENT.
2. SEE PRICE PAGES FOR THERMOSTAT AND SUBBASES.
3. USE 75 DEGREE COPPER CONDUCTORS FOR FIELD INSTALLATION.
4. REFER TO INSTALLATION INSTRUCTIONS
FOR CORRECT SPEED SELECTION OF IFM.
5. RELOCATION OF SPEED TAPS MAY BE REQUIRED
WHEN USING FIELD INSTALLED ELECTRIC HEATERS,
CONSULT INSTALLATION INSTRUCTIONS TO
DETERMINE CORRECT SPEED TAP SETTING.
6. "DO NOT DISCONNECT PLUG UNDER LOAD."
7. THIS FUSE IS MANUFACTURED BY LITTELFUSE, P/N 257003.
8. UNIT FACTORY-SHIPPED IN STD MODE.
A10205