Munchkin Controller - Heat Transfer MUNCHKIN Operating Manual

High efficiency heater with the 925 controller
Table of Contents

Advertisement

e. Replace the (4) screws on the aluminum ½" NPT connector on the gas valve. Turn the gas
back on. (IMPORTANT: CHECK FOR GAS LEAKS)
f.
Re-set thermostats (IMPORTANT: MAKE SURE EXHAUST VENT IS NO LONGER BLOCKED!)
g. Turn the Munchkin back on** and observe condensate flow.
h. Re-connect the condensate hose to the outside connection.
IT IS EXTREMELY IMPORTANT THAT YOU CHECK FOR LEAKS WHEN
RECONNECTING THE GAS VALVE AND MAKING SURE THE EXHAUST VENT IS NO
LONGER BLOCKED. FAILURE TO DO SO MAY RESULT IN SEVERE PERSONAL INJURY
OR DEATH.
**NOTE: When firing up the boiler for the first few times you may experience some flut-
tering of the gas burner that may result in a flame lockout. This is normal and will
require you to re-cycle the unit until this clears up. This is caused by water still present
in the combustion chamber.
E. MUNCHKIN CONTROLLER
Fig. 8-1
There is a spare 6.3 amp "slow blow" fuse included on the control cover. HTP p/n 7250-378 or
*
you may purchase it from Radio Shack p/n: 270-1068
Caution: Do not replace with any amperage other than 6.3A
DANGER
CONTROL WIRING LAYOUT
MAINTENANCE
43