Disassembly And Reassembly - Samsung MW5580W Service Manual

Table of Contents

Advertisement

4. Disassembly and Reassembly

4-1 Replacement of Magnetron, Motor Assembly and Lamp
Remove the magnetron including the shield case,
permanent magnet, choke coils andF capacitors (all
of which are contained in one assembly).
1. Disconnect all lead wires from the magnetron
and lamp.
2. Remove a screw securing the magnetron
supporter.
3. Remove the magnetron supporter.
4. Remove the air cover.
5. Remove screws securing the magnetron to the
wave guide.
6. Take out the magnetron very carefully.
7. Remove screws from the back panel.
8. Take out the fan motor.
9. Remove the oven lamp by rotating to pull out
from hole of air cover.
NOTE1: When removing the magnetron, make
sure that its antenna does not hit any
adjacent parts, or it may be damaged.
NOTE2: When replacing the magnetron, be sure
to remount the magnetron gasket in
the correct position and make sure the
gasket is in good condition.
4-2 Replacement of High Voltage Transformer
1. Discharge the high voltage capacitor.
2. Disconnect all the leads from the high voltage
transformer.
3. Remove the mounting bolts on the high voltage
transformer.
4. When replacing, connect the leads correctly and
firmly.
Samsung Electronics
Lamp
Supporter MGT
Magnetron
Thermo S/W
Fan Motor
H. V. Trans H. V. Capacitor
H. V. Trans
Screws
Nuts
4-1