Samsung SP0211N Service Manual page 36

Palo(p80)series
Table of Contents

Advertisement

SAMSUNG HARD DISK DRIVE
mode, and extend capacity by raising the number of cylinder. Currently most of hard disk
is applied to LBA mode, so it set as LBA or AUTO in BIOS set-up.
4) PC is downed with the message of "Stack Over Flow" while HDD running or can't recognize
HDD.
If internal stack overflow error occurred on the basis of MS-DOS system
(MS-DOS, MS-WINDOWS95), increase the number of internal stacks of CONFIG.SYS file and
the usages are as follows.
STACKS=number,size
This number means the number of stacks (it is possible to designate by 8-64, Default 9),
and the size means stacks' size. (32-512, Default 128)
"Internal stack overflow" occur on using the program which can make memory assigned stack
region apply hardware work, and also this problem occur during progress of RAM residential
program or applicable program on the basis of non-windows system.
5) Bad Sector often occur.
Hard disk is supported by IDE system under the 486 computer. IDE system can set to the
extent of 2 hard disks and though it was set high capacity hard disk, the real capacity
is up to 528MB. From 529MB, EIDE( extended IDE) type supporting computer re cognize as
Bad Sector. If your computer doesn't support EIDE, you can use disk manager program,
you can download this in utilities of our web-site.
In times of CMOS set-up, make Hard disk recognized as Auto Defect in EIDE supporting
computer and make HDD mode to LBA if BIOS is AMI,Award.
6) Parking should be necessary when turn PC off?
HDD which can't supporting Auto parking has been damaged by stopping read/write head on
data region if it is off suddenly. To protect this problem, we have to move head to
parking region by parking program but we need not progress additional parking program to
move head to parking head.