Important Safeguards. ▲Never arbitrarily disassemble, repair or restructure the apparatus. It must be serviced by the manu- facturer, its service agent or similarly qualified persons in order to avoid a hazard ▲Any change to the humidifier may cause hazard without our company’s permission. ▲If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
1.Technical data Model: MJS-500 MJS-400 Rated voltage: 220V-240V - 50Hz Rated power: 30W Tankage: 5L Mist: ≥260mL/H Noise: <35dB 2. How to use MJS-500 1)Put the humidifier on a suitable place and take off the tank. Unscrew the cover and fill the tank with clean tap water or distilled water.
Page 4
10.Main body 11.Power switch 12. Environmental humidity and set humidity display 13. Water-short 14. Environmental temperature and set hours display 15. Mist settings and water flow indicator MJS-500 1..Handle 2.Air flow outlet 3.Tank 4.Cover 5.Power switch 6.Power cord 7.Main body 8.Display...
Page 5
3. Cleaning and replacement of Water filter 1) Water filter is consists of core box, cover and nano silver ion ce- ramic balls. Caution: Do not disassemble Water filter. Please clean and replace it according to the introduction. 2) Water quality: nano silver ceramic balls sterilize microbe. 3) The Water filter should be cleaned every one or two months.
6. Troubleshooting PROBLEM CAUSE SOLUTION Standby indicator isn’t working, Power not connected Connect the power plug no wind; no mist. Water-short indicator on; Short of water Fill with water in the tank no wind; no mist Mist with abnormal smell New appliance / Open the tank and put the mouth of the tank in shade for 12 hours...