3.1. Preparation
1) Allow approximately 30 minutes for the set to warm up before proceeding with the white
balance adjustment.
2) Connect 3 terminal of 480i signal cable (Y / Pb / Pr) from the signal source to monitor
INPUT3
3) Enter "SERVICE MODE". The method to enter "SERVICE MODE" is described in next
section.
4) Select "VIDEO3" from INPUT SOURCE in SERVICE MENU
5) Set "R" ,"G" ,"B" ,"GAIN" and "R" ,"G" ,"B" ,"Offset" value as same as
"3.5. AVERAGE VALUE"
3.2. Adjust White Balance of "COOL" temperature;
1) Select "COOL" from COLOR TEMPERATURE in SERVICE MENU
2) Input 65IRE Full white pattern signal into INPUT3
3) Adjust "RGB GAIN" in SERVICE MENU if needed
4) Input 30IRE Full white pattern signal into INPUT3
5) Adjust "RGB OFFSET" in SERVICE MENU if needed
6) Repeat adjustment of 2) to 5) so that White Balance is as same level as good monitor
3.3. Adjust White Balance of "NEUTRAL" temperature;
7) Select "NEUTRAL" from COLOR TEMPERATURE in SERVICE MENU
8) Repeat adjustment as same step of 2) to 5) till White Balance is as same level as good
monitor
3.4. Adjust White Balance of "WARM" temperature;
9) Select "WARM" from COLOR TEMPERATURE in SERVICE MENU
10) Repeat adjustment as same step of 2) to 5) till White Balance is as same level as good
monitor
KLV-32U100M/KLV-40U100M
SECTION 3 : ADJUSTMENT
KLV-32U100M/KLV-40U100M