V I I I . B A S I C T R O U B L E S H O O T I N G
Any electromechanical device occasionally requires some troubleshooting. However, most of the
problems that may arise can usually be solved with a bit of thought and common sense. Many of these
problems occur because the batteries are not fully charged or because the batteries are worn down and can
no longer hold a charge.
DIAGNOSTIC FLASH CODES
The diagnostic flash codes for your scooter are designed to help you perform basic troubleshooting quickly
and easily. A diagnostic flash code flashes from the status LED in the event one of the conditions listed
below develops.
NOTE: Your scooter will not run unless the flash code condition is resolved and the scooter has been
turned off, then turned back on.
FLASH CODE
(1, 4)
(2)
(3, 1)
(3, 2)
(1, 5)
What if all the systems on my scooter seem to be "dead"?
Make certain that the key is in the "on" position.
Check that the batteries are fully charged. See IV. "Batteries and Charging."
Push in the main circuit breaker reset button. See III. "Your Scooter"
Make certain that both battery harnesses are firmly connected to the electronics module and to the
battery terminals. See VII. "Disassembly and Assembly."
Make sure that the front-to-rear harness is firmly connected to the electronics module. See VII.
"Disassembly and Assembly."
Check the fuses. See IX. "Care and Maintenance" for fuse replacement.
Be sure the power down timer feature has not been activated. See V. "Operation.".
Maxima
CONDITION
Batteries are too low to operate
the Maxima or the charger is
operating.
Controller is hot; the Maxima
seems to be losing power.
Wigwag fault; your throttle con-
trol lever is not responding.
The manual freewheel lever is in
the (up) freewheel position.
The Maxima is operating with the
charger attached.
www.pridemobility.com
SOLUTION
Charge batteries or unplug the
charger power lead from the
electrical outlet.
Shut down your Maxima for
several minutes to allow the
controller to cool.
Call your authorized Pride Pro-
vider for assistance.
Turn the Maxima key to the off
position, then push the manual
freewheel lever to the (down)
drive position, and restart your
Maxima.
Unplug the charger power lead
from the off-board charger port.