ZyXEL Communications SHD1110 Quick Start Manual
ZyXEL Communications SHD1110 Quick Start Manual

ZyXEL Communications SHD1110 Quick Start Manual

Temperature/humidity detector
Hide thumbs Also See for SHD1110:

Advertisement

Quick Links

SHD1110

Quick Start Guide

Temperature/Humidity
Detector
Version 1.00
Edition 1, 7/2011
2011 ZyXEL Communications Corporation
www.zyxel.com
C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SHD1110 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ZyXEL Communications SHD1110

  • Page 1: Quick Start Guide

    SHD1110 Quick Start Guide Temperature/Humidity Detector Version 1.00 Edition 1, 7/2011 2011 ZyXEL Communications Corporation www.zyxel.com...
  • Page 2: Front And Back Panels

    Front and Back Panels LCD screen Function keys Select modes/Change setting Select temperature unit/ Include/Associate device to Z-Wave Network Increase settings, displays maximum temperature/humidity or enable RF & beep tone Decrease settings, displays minimum temperature/humidity or disable RF & beep tone Temperature/humidity sensor Mounting bracket LCD Display...
  • Page 3: Installing The Batteries

    The SHD1110 is designed to monitor the current temperature and humidity of ambient environment. If temperature/humidity reaches the set points, the SHD1110 will send alerts to associated devices for further actions, such as trigger air conditioner or dehumidifier to power on/off automatically when used with Z-Wave power switch.
  • Page 4 Adding to Z-Wave Network When the SHD1110 is powered up for the first time, the reading in RF mode is 00 which implies that it has not been allocated a node ID and cannot work with Z-Wave enabled devices. You can use the [ ] key on the SHD1110 to include, exclude, associate with a Z-Wave Network, or reset.
  • Page 5 ID has suceeded or failed. • For the first 10 minutes after you install the batteries and include the SHD1110 to your Z-Wave network, it can associate with the Z-Wave Controller and other nodes automatically. After 10 minutes, you need to follow the steps in the above table to enter association mode.
  • Page 6: Wall Mounting

    2. Once snapped in place, the SHD1110 can be placed on a shelf, table or other surface where you wish to detect temperature and humidity. Wall-Mounting 1. Place mounting bracket over a desired location on the wall. Through the 3 screw holes of the bracket, mark the mounting surface with a pencil.
  • Page 7: Temperature Settings

    Temperature Settings Displaying Current Temperature 1. Press [ ] and select Mode 1 to display current temperature, and toggle [ ] to select the unit of temperature ( Mode 1 2. The temperature ranges from -20 C to 50 C). To show the last record of max/min temperature, press [ ] or [ ].
  • Page 8: Humidity Settings

    The record is cleared after a long beep is sounded. 5. If the temperature reaches the preset trigger-ON/OFF value, the SHD1110 will send out RF signals. The screen returns to Mode 1 and the icon [...
  • Page 9 50%, the trigger-OFF humidity cannot be between 45% and 55%. Note: Once the SHD1110 has been triggered, the humidity must raise up or drop down at least 5% from the preset value before it can be triggered again.
  • Page 10 Mode 7 ] to disable it. Note: If the RF mode is OFF, no command will be sent even if the SHD1110 has been triggered. If RF is ON and the SHD1110 has been triggered, the RF command will be sent to nodes of Grouping 2 (see the User’s Guide for more information on Z-Wave Grouping).
  • Page 11: Toubleshooting

    The SHD1110’s A malfunction has 1. Remove and reinstall the reading is occurred. batteries to reset the incorrect. SHD1110. Follow the steps in the Installing the Batteries section. 2. If the problem continues, contact your vendor.