Panasonic CS-S18HKH Service Manual page 41

Table of Contents

Advertisement

• Indicator
- When e-ion operation starts, e-ion indicator ON.
• Remote Control Receiving Sound
- Normal Operation
- e-ion Operation
- Stop
- e-ion individual Operation
• Power failure
- During e-ion individual operation, if power failure occurs, after power resumes, e-ion individual operation resumes
immediately.
- During combination operation, if power failure occurs, after power resumes, combination operation resume immediately.
- e-ion operation status is not memorized after OFF the unit. After OFF, when the operation is ON again, air conditioner
operates without e-ion operation.
• e-ion Check Mode
- To check if e-ion is malfunctioning, during e-ion operation press e-ion button for 15 seconds and release to enter e-ion Check
Mode and supplies power to the Active e-ion Air Purifying System.
- If abnormal discharge is detected at filter (short-circuited) due to water or dust adhesion, etc., the e-ion indicator blinks
immediately.
• Error Detection Control
When e-ion indicator blink, it indicates error listed below:
- Active e-ion Air Purifying system PCB main connector open:
Judgment Method
• During e-ion operation (include during Patrol operation), active e-ion Air Purifying system main connector to PCB is
opened.
Troubleshooting Methods
• Connect the connector or stop operation (include during Patrol operation) to cancel the blinking.
- Abnormal Discharge error:
Judgment Method
• During e-ion operation, feedback voltage is-Lo (at microcontroller) is detected, it is judged abnormal discharge and
stops power supplies to the active e-ion Air Purifying system.
• Abnormal discharge is caused by ionizer or filter's high voltage power supply short-circuits due to water or dust
adhesion, and so forth.
• When abnormal discharge occurred, every 30 minutes the unit supplies power to the active e-ion Air Purifying system.
• When abnormal discharge occurs for 24 times continuously, e-ion indicator blinks (not applicable for e-ion Check
Mode, where the error will shows immediately despite the 24 times counter).
Troubleshooting Method
• Press "e-ion" button or "OFF/ON" button to stop the operation and check the active e-ion Air Purifying system main
connector to PCB.
• After that, press "e-ion" button again to confirm the e-ion indicator not blinking.
• The 24 times counter will be clear after 10 minutes of normal operation or when operation stops.
Error Reset Method
• Press "OFF/ON" button to OFF the operation.
• Press AUTO OFF/ON button at indoor unit to OFF the operation.
• OFF Timer activates.
• Press "e-ion" button during e-ion individual mode.
• Power supply reset.
e-ion Operation
Normal Operation
e-ion individual Operation : Beep
Stop
41
: Beep
: Beep
: Long Beep