Dimplex EUL-B Series Installation Instructions page 2

Electric unit heaters

Advertisement

Figure 2
OpTiOnaL COnTrOLS
integral thermostats
built-in snap-action thermostat. The sensing element
is located in the return air stream to provide accurate
temperature control. The thermostat has a range of 40
F (low) to 100 F (high). It can be manually operated or
rendered tamper-proof as desired. This control can be
field-mounted or factory mounted.
remote Line voltage Thermostat
connected to a line-voltage remote thermostat. A special
control terminal block is provided in all units to facilitate
easy connection of the remote thermostat control wiring.
remote Low voltage Thermostat with relay
voltage transformer/relay can be field or factory installed
with the unit for remote low voltage thermostatic control.
The special control terminal block is utilized for this
optional control feature.
1367 Industrial Road
Cambridge ON Canada N1R 7G8
1-888-346-7539
www.dimplex.com
In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.
© 2011 Dimplex North America Limited
2
- All units are available with a
- All units can be
Fan-Only Switch -
available for integral mounting within the unit. This
switch provides continuous fan-operation, independent of
the built-in or optional remote thermostatic control, which
is effective in eliminating air stratification.
STarT Up
1.
Before the unit is energized, the discharge louvres
should be adjusted for desired air deflection.
2.
Check to see that all controls and optional accessories
are operation properly.
Maintenance
CaUTiOn: Before removing the front cover for cleaning,
make certain the power has been turned off at the circuit
breaker panel.
CaUTiOn: Allow adequate time for the element and body
casing to cool before attempting to work on the heater.
1.
Under normal conditions, the heater should be cleaned
once a year. DISCONNECT ALL POWER before
cleaning or servicing the heater.
2.
All motors are lubricated for extended life operation, and
will not have to be oiled.
Warranty
The Manufacturer warrants the heating elements and components
of the enclosed product against any defect in material or
workmanship for a period of one year from the date of purchase. In
full satisfaction of any claims under this Warranty the Manufacturer
will repair or replace without charge, in its factory or in the field as it
alone may decide, any parts which in its opinion are defective.
The Manufacturer shall not be responsible for any transportation
or shipping costs in relation to such repair or replacement except
as specifically assumed by it. Misuse of this product or repairs by
persons other than the Manufacturer's authorized personnel without
the Manufacturer's written approval, will void this Warranty.
This Warranty is in lieu of all other warranties or conditions
whether express or implied including but not limited to those of
merchantability or fitness for purpose and shall constitute the sole
remedy of the Purchaser and the sole liability of the Manufacturer in
respect of the sale of the product, whether in the nature of breach or
breach of fundamental term, or of negligence or otherwise.
The Manufacturer shall not be liable for any special, indirect or
consequential damages or for any damages resulting from removal
- A low
or replacement of a heater subject to warranty claim without the
Manufacturer's authorization.
This Warranty is transferable by the original consumer purchaser
of the product. Any claims under this Warranty must be submitted
in writing to the Service Manager, Dimplex North America Ltd., 1367
Industrial Rd., Cambridge, Ontario N1R 7G8, Canada.