Set Up The Product; Basic Setup; Focus Adjustment; Back Focus Adjustment - Axis M1114 User Manual

Hide thumbs Also See for M1114:
Table of Contents

Advertisement

AXIS M1114

Set Up the Product

Set Up the Product
The Axis product can be configured by users with administrator or operator rights. To open the product's Setup pages, click Setup in
the top right-hand corner of the Live View page.
Administrators have unrestricted access to all settings.
Operators have access to all settings except System Options
See also the online help

Basic Setup

Basic Setup provides shortcuts to the settings that should be made before using the Axis product:
1. Users. See page 38.
2. TCP/IP. See page 40.
3. Date & Time. See page 40.
4. Video Stream. See page 16.
5. Focus. See page 15
The Basic Setup menu can be disabled from System Options > Security > Users.

Focus Adjustment

The focus can be adjusted under Basic Setup > Focus. Follow the on-screen instructions to adjust the focus. For further information
about focus, refer to the product's Installation Guide.

Back Focus Adjustment

If the lens is changed to a non-standard lens or when the focus achieved is not satisfactory, adjust the back focus as follows:
1. Loosen the screw that holds the CS-ring. See Hardware Overview on page 6
2.
Direct the camera towards an object at least 7 meters away and check that it is possible to focus the camera in both max
wide and max tele angles (adjust with the zoom puller).
3. Direct the camera towards a close object, about 30 cm away and check that it is possible to focus the camera in both max
wide and max tele angles (adjust with the zoom puller).
4. If it is not possible to focus the camera in step 2 or 3, adjust the CS-ring and go back to step 2.
5. Gently tighten the screw to secure the CS-ring's position.
6. Adjust the zoom and focus position for the desired view.
.
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M1103

Table of Contents