fi-6800 C
R
ONSUMABLE
EPLACEMENT AND
22
C
I
LEANING
NSTRUCTIONS
C
G
A
LEANING THE
LASS
REAS
•
Clean the Glass Areas on the lower side of the ADF with a lint free
cloth.
Removable Glass
Non-Removable Glass
Note:
Under normal conditions the Removable Glass assembly should not
have to be removed. If there is a large amount of paper dust in the
scanner and the scanned images continue to have vertical streaks,
follow the directions below to clean behind the glass.
•
Loosen the screw on the Glass
Assembly. This is a captive
screw so it will not come free.
•
Tilt the Glass to the angle shown
on the right.
•
Remove the Glass as you slide it
to the left.
•
Clean the backside of the glass
you removed with a lint free
cloth.
•
Using a cotton swab, clean the
glass inside the area where the
Glass was removed.
•
Reinstall the Glass Assembly.
•
Reset the Cleaning Counter in the Software Operation Panel or on the
Scanner Operator Panel.
(
.)