Connecting To Gas Supply; Check Gas Type - Comfort Glow HFVMR18 Owner's Operation And Installation Manual

Natural gas log vented decorative appliance
Table of Contents

Advertisement

INSTALLATION
Continued
MODEL
DESCRIPTION
HFVMR18 18" Multi-Side
HFVMR24 24" Multi-Side
MINIMUM FIREBOX SIZES
LOG FRONT
SIZE WIDTH* WIDTH** DEPTH HEIGHT
18"
28"
3
24"
29
/
"
4
* Add 6" if safety valve/pilot is used
**At depth indicated
FUEL INLET PRESSURE
SPECIFICATIONS (W.C.)
NG
LP
BURNER ORIFICE
LOG
NATURAL
SIZE
IN.
18"
.111
24"
.129
Figure 2 - Technical Information Charts

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, you must
install ON/OFF Safety Valve/Pilot Kit (see Accessories, page 17).
Call dealer where you bought log set.
If the fireplace does not have a gas supply shut-off valve, one must
be installed.
VENTING SPECIFICATIONS FOR
INSTALLATION
The fireplace chimney flue and vent must be drafting properly. To
check the vent for proper drafting: Light a tightly rolled newspaper
on one end and place it at the inside front edge of the fireplace.
Observe the smoke and be sure the vent is properly drawing it up the
chimney. If the smoke spills out into the room, extinguish the flame
and remove any obstruction until proper venting is achieved.
The chimney flue must remain open a minimum of 3" at all times
during the operation of this log set.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901915-01B
Btu Input
Btu Input
Propane/LP
Natural
Gas
Gas
55,000
45,000
65,000
55,000
BACK
28"
16"
18"
3
29
/
"
16"
18"
4
Min.
Max.
5.5"
10.5"
11"
13"
PROPANE/LP
NUM.
IN.
NUM.
34
.073
49
30
.086
44
Venting Specifications for Installation
INSTALLING DAMPER CLAMP
Minimum
Vent
Secure the damper stop clamp provided to the leading edge of the
Opening
damper as shown in Figure 3. If for any reason this clamp doesn't
8" dia.
work on your fireplace, another suitable clamp or permanent stop
8" dia.
must be installed, or the damper blade must be cut or removed.
Damper
Masonry Fireplace
Figure 3 - Attaching Damper Clamp

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must con-
nect log set to gas supply. Follow all local codes.
Installation Items Needed
Before installing log set, make sure you have the items listed below.
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve
• test gauge connection
• adjustable (crescent) wrench or pliers
• sediment trap
• tee joint
• pipe wrench
CAUTION: Use only new, black iron or steel pipe.
Internally-tinned copper tubing may be used in certain
areas. Check your local codes. Use pipe of 1/2" diam-
eter or greater to allow proper gas volume to log set. If
pipe is too small, undue loss of volume will occur.
INSTALLATION
Flue Opening Specifications (Cont.)
Check Gas Type
Installing Damper Clamp
Connecting To Gas Supply
Damper Clamp
Damper
Manufactured Fireplace
5 5
Damper Clamp