_ Electric Cookers _ rev. 1 _________________________________________________________ KCV 96 P – KCV 96_
Technical specifications
Technical specifications
Technical specifications
Technical specifications
Model
Model
Model
Model
Overall dimensions
Oven dimensions
Usable oven volume
Tray maximal load (GN 1/1)
Total load (4 trays GN 1/1)
Electrical capacity of grill heating
element
Electrical capacity of oven
Maximum electrical capacity
Power supply voltage
Frequency
Class
Nominal thermal capacity
Appliance category
(for United Kingdom)
Gas connection
Installation class
Factory adjustment
Supply nominal pressure values
The "technical data" page is located on the rear panel of the appliance.
The "technical data" page is located on the rear panel of the appliance.
The "technical data" page is located on the rear panel of the appliance.
The "technical data" page is located on the rear panel of the appliance.
2. 2. 2. 2. Flush fitting in unit furniture
Flush fitting in unit furniture
Flush fitting in unit furniture
Flush fitting in unit furniture
The appliance can be installed as follows (Fig. 1):
- Stand-alone, away from other forniture (class 1);
- Fitted between two forniture units (class 2 –
subclass 1).
In compliance with safety regulations, protection
against possible contact with electrical parts and
against overheating of furniture in contact wst the
appliance, must be ensured by correctly flush fitting
the appliance.
May we remind you that, for layers in plastic or
veneered wood in unit furniture, glues resisting a
temperature of 120°C must be used. Plastics or
glues of poorer quality not able to withstand this
temperature value, will cause deformation and glue
detachment.
Make absolutely sure that the rear of the appliance always rests against non flammable walls.
Set the basement zone free.
If the cooking range is positioned on a pedestal, the appropriate measures must be taken to
ensure that it never slides off or tips over from the pedestal.
_ CATEGORY II2H3+ _ GB __
LxDxH
(mm)
LxDxH
(mm)
3
(dm
)
kg
kg
(W)
(W)
(W)
(V~)
(Hz)
(kW)
Liquid gas G30 / G31: 30/37 mbar - Natural gas G20: 20 mbar
_____________________________________________________ page 7 _
0705
KCV 96 P
KCV 96 P
KCV 96 P
KCV 96 P
900x600x850
510x410x345
72
4
16
2500
2400
2530
220-230
50
I (against electric shocks)
14.25
II2H3+
½" " " "
Class 2 - subclass 1 / Class 1
Natural gas G20 – 20 mbar
KCV 96
KCV 96
KCV 96
KCV 96
5000
5150
380-400 2N
Fig. 1