VOICE VECTOR
X-axis & Y-axis
Summary: These parameters define the position of
the currently selected step on the X and Y axes
of the detune vector control range.
Settings:-31 ... 0 ...+31
Procedure: Use the
place the underline cursor under the X or Y
parameter. Use the [-1/NO] and [+1/YES] keys
to set the value as required.
Details: On the X (D-C) axis, a setting of -31
places the step as far as possible toward the D
element while a setting of +31 places it as far as
possible toward the C element. The Y (A-B)
axis values work in the same way: a setting of
-31 places the step as far as possible toward
the B element while a setting of +31 places it as
far as possible toward the A element. In both
axes a setting of 0 places the step at center
position.
D
Xaxis
Refer to: Tutorial, page 21-24.
40
and
cursor keys to
A
C
B
Yaxis
Time
Summary: Multiplies the vector rate setting of the
current detune vector step only. Also allows
vectors to be looped or ended at the current
step.
Settings: 1 ... 254, Repeat, End
Procedure: Use the
place the underline cursor under the rightmost
value on the lower display line (Time). Use the
[-1/NO] and [+1/YES] keys to select the re-
quired time value.
Details: Time values multiply the vector rate set-
ting for the current step. If the vector rate
parameter is set to 30ms, for example, setting
the time parameter to 2 results in a step length
of 60ms, setting it to 3 results in a step length of
90ms, and so on. Since the maximum time value
is 254, extremely long steps can be created.
If you select the "End" setting, the vector will
end at the current step.
The "Repeat" setting causes the vector to loop
back to the first step from the current step,
repeating continuously.
Refer to: Tutorial, page 21-24.