Dacor CM24T-1 Installation Instructions Manual
Dacor CM24T-1 Installation Instructions Manual

Dacor CM24T-1 Installation Instructions Manual

Automatic coffee system

Advertisement

Part No. 101334 Rev. E
a
c
u tom atI c
For use with models:
CM24T-1
CM24P-1
I
nsta ll atI o n
s
o ffee
ystem
I
nstru c tI o ns

Advertisement

Table of Contents
loading

Summary of Contents for Dacor CM24T-1

  • Page 1 For use with models: CM24T-1 CM24P-1 Part No. 101334 Rev. E...
  • Page 3: Table Of Contents

    Customer: Keep these installation instructions for future reference and the local electrical inspector’s use. If you have questions or problems with installation, contact ® your Dacor dealer or the Dacor Customer Service Team. Dacor Customer Service Team Phone: (800) 793-0093 Email: customerservice@Dacor.com...
  • Page 4: Important Safety Instructions

    mportant afety nstructIons To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety precautions, including the following: WARNING If the product is damaged, immediately contact the dealer or builder. Do not install or use a damaged appliance. Do not use the coffee system until it has been properly installed by a qualified installer according to these installation instruc- tions.
  • Page 5: Product Specifications

    Power Cord Length 60 inches Unit Weight 110 lbs. Shipping Weight 139 lbs. Fresh Water Capacity 5 Liters/1.3 Gallons (Model CM24T-1 only) 17 9/16” 18 3/16” (445mm) Minimum Regulated 1.5 Bar (21.8 psi) at regulator (462mm) Input Pressure output connection Maximum Regulated 3.0 Bar (43.5 psi) at regulator...
  • Page 6: Installation Specifications

    Pressure regulator (model CM24P-1 only) If the water supply is unfiltered, you may attach the • Pressure regulator bracket (model CM24P-1 only) optional filter cartridge (Dacor P/N ACWF) to the filter • Pressure gauge (model CM24P-1 only) head to improve water taste.
  • Page 7: Location Requirements

    ® • Dacor cannot be held responsible for damage to property or injury to persons caused by failure to comply with the installation, maintenance, and safety instructions contained in this handbook. • Statutory regulations and the connection specifications issued by the local power supply company must be strictly observed.
  • Page 8: Nominal Cutout Dimensions

    ImensIons Ventilation opening in Overhanging back of cabinet cabinet 4” X 12” Min. (100mm X 300mm) Vertical Distance CM24T-1 14” Minimum Veritical distance to overhanging cabinet CM24P-1 6” Minimum 14” Minimum During normal operation, the user must have access to the top of the unit. The...
  • Page 9: Steam Barrier

    nstallatIon nstructIons team arrIer • Remove the coffee system from the packaging and inspect it for damage. Do not install a damaged system. • Insert the steam barrier into the top of the cut-out. Push it all the way to the back so that the back of it lines up with the back wall of the cabinet.
  • Page 10: Plumbing Installation (Model Cm24P-1 Only)

    nstallatIon nstructIons lumbIng nstallatIon • Connect the hose connected to the appliance to cm24p-1 o the output of the regulator. Pay attention to the odel flow direction arrows on the pressure regulator. IMPORTANT: If you connect the hoses to the regulator CAUTION backwards, the water will not flow into the coffee To prevent damage to the coffee system due to hard water, prior...
  • Page 11: Installing The Cabinet Glides

    nstallatIon nstructIons nstallIng the abInet lIdes • Put the two cabinet glide assemblies, and shims if The cabinet glides mount to the inside of the cabinet. necessary, as shown on the inside surfaces of the The glides on the coffee system slide into the cabinet cabinet.
  • Page 12: Installing The Coffee System In The Cabinet

    Check to make sure the pressure regulator is set between 1.5 bars to 3 bars pressure. Adjust the regulator if necessary. On model CM24T-1 (tank model): Fill the tank with filtered water (4 gpg maximum water hardness, do not use distilled water).
  • Page 13: Installation Checklist

    nstallatIon nstructIons nstallatIon hecklIst WARNING • To ensure a safe and proper installation, the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked. • Proper installation is the responsibility of the homeowner.
  • Page 14: Notes

    otes...
  • Page 16 Web Site: www.Dacor.com Copyright © 2007 by Dacor Inc. All rights reserved. Phone: (800) 793-0093...

This manual is also suitable for:

Cm24p-1

Table of Contents