Service Test Program; Demo Mode - Philips FWM390 Service Manual

Mini system
Hide thumbs Also See for FWM390:
Table of Contents

Advertisement

SERVICE TEST PROGRAM

TUNER
QUARTZ
TEST
TEST
N
TUNER
Button pressed?
Y
Display Tuner Version
"ccc"
N
TUNER
Button pressed?
Y
Service frequencies are
copied to the RAM (see Table1)
Tuner works normally
except:
PROGRAM button
N
Disconnect
Mains cord ?
Y
Service Mode left
Europe
East Eur. Extended-band
East Eur.
PRESET
"EAS"
"EUR"
"EAS"
1
87.5MHz
65.81MHz
87.5MHz
2
108MHz
108MHz
108MHz
3
531kHz
74MHz
531kHz
87.5MHz
4
1602kHz
1602kHz
531kHz
5
558kHz
558kHz
1602kHz
6
1494kHz
1494kHz
7
558kHz
153kHz
87.5MHz
8
279kHz
1494kHz
87.5MHz
9
198kHz
98MHz
87.5MHz
10
98MHz
70.01MHz
87.5MHz
65.81MHz
11
87.5MHz
98MHz
Table 1
Note: * Depending on the selected grid frequency (9 or 10kHz)
By holding the TUNER and R buttons depressed while switching on the Mains supply, one
of the undermentioned features will be activated:
- the tuning grid frequency is toggled between 9kHz and 10kHz for the Oversea (/21) version.
- the extended FM1 (65.81MHz - 74MHz) is toggled on and off for East Eur. (/34) version.
3-1
To start service test program
hold P & AUX
depressed while
plugging in the mains cord
S refers to Service Mode.
Display shows the
ROM version *
V refers to Version.
"S-Vyy"
(Main menu)
yy refers to Software version number of Processor.
(Counting up from 01 to 99)
N
O
STANDBY-ON
Button pressed?
Button pressed?
Y
Display shows
Set is in Service PLAY Mode.
32K
Output at (Front Board)
In case of failures, error
pin 80 of uP = 2048Hz
codes according to table 2
will be displayed.
The Service Play Mode is intended to
O
N
detect and identify the failures in the CD Mode.
Button pressed?
In this mode the electronics will still function
even when an error is detected so that
repair activities can be carried out.
Y
Display shows
8M
Output at (Front Board)
pin 80 of uP = 1,953.125Hz
9
N
Error code
Button pressed?
E1000
Y
E1001
E1002
USA
Oversea
"USA"
"OSE"
E1003
87.5MHz
87.5MHz
108MHz
108MHz
E1005
530kHz
530/531kHz*
1700kHz
1700/1602kHz*
E1006
560kHz
560/558kHz*
1500kHz
1500/1494kHz*
E1007
98MHz
98/87.5MHz*
87.5MHz
87.5MHz
E1008
87.5MHz
87.5MHz
87.5MHz
87.5MHz
E1020
87.5MHz
87.5/98MHz*
E1070
E1071
E1079
SERVICE
PLAY MODE
N
Y
note 1 :
All LEDs are on except ECO POWER.
note 2 :
Only DISC 2, TUNER, AUX, DSC, VEC & MAX SOUND are on.
Error Description
Focus Error
Triggered when the focus could not be found within a certain time when starting up the CD
or when the focus is lost for a certain time during play.
Radial Error
Triggered when the radial servo is off-track for a certain time during play.
Sledge In Error
The sledge did not reach its inner position (inner-switch is still close) before approximately
6 Sec. have passed by. Inner-switch or sledge motor problem.
Sledge Out Error
The sledge did not come out of its inner position (inner-switch is still open) before approximately
250 mSec. have passed by. Inner-switch or sledge motor problem.
Jump-offtrack error
Triggered in normal play when the jump destination could not be found within a certain time.
When this error occurred, software will try to recover by initiating the jump command again.
If it is recoverable, the disc will continue to play.
Subcode Error
Triggered when a new subcode was missing for a certain time during play.
PLL Error
The Phase Lock Loop could not lock within a certain time.
Turntable Motor Error
Generated when the CD could not reached 75% of speed during startup within a certain time.
Discmotor problem.
Focus Search Error
The focus point has not been found within a certain time.
This happens when the carousel switch is defective and closed all the time, or when the
carousel is blocked when it is located exactly at a disc position.
This happens when the carousel switch is defective and does not closed electrically, or when
the carousel is blocked in between two disc positions. The time-out is approximately 5 Sec.
The drawer could not open or enter the inside position and is opening again. This happen when
the drawer is blocked and cannot go fully inside or when the drawer switch is defective and does
not close.
Table 2
3-1

DEMO Mode

ACTION
Hold the 9 button down for 5 seconds during the DEMO display,
To Switch off
the set will confirm with "DEMO OFF" and switch to Standby.
Hold the 9 button down for 5 seconds during Standby, DEMO
To Switch on
will begin.
DISPLAY
TEST
Button pressed?
Display shows Fig. 1
and selected LEDs on
Figure 1
(see note 1)
Button pressed?
Display shows Fig. 2
and selected LEDs on
Figure 2
(see note 2)
Button pressed?
TEST
Activated with
EEPROM TEST
EEPROM FORMAT
ROTARY
ENCODER TEST
LEAVE SERVICE
TESTPROGRAM
Mini 2002 FW-C399 Dated: wk141
N
2;
Y
N
2;
Y
9
N
Y
Various
other Tests
ACTION
R
A test pattern will be sent to the EEPROM.
"PASS" is displayed if the uProcessor read
back the test pattern correctly, otherwise
9 to Exit
"FAIL" will be displayed.
Q
Load default data. Display shows "NEW"
for 1 second.
Caution!
All presets from the customer will be lost!!
Volume Knob
Display shows value for 2 seconds.
or
Values increases or decreases in steps of 1
Jog Shuttle knob
until 0 (Min.) or 40 (Max.) is reached.
Disconnect
mains cord

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents