Electrical Adjustment
Grp / No. Item
205
Spread Spectrum
0
1
2
210
Lamp Contorl
0
Dimmer SW
1
Manual Control
2
DIMMER_CTRL_LEVEL1
3
DIMMER_CTRL_LEVEL2
4
DIMMER_CTRL_LEVEL3
5
DIMMER_CTRL_LEVEL4
6
DIMMER_CTRL_LEVEL5
7
DIMMER_CTRL_LEVEL6
8
DIMMER_CTRL_LEVEL7
9
DIMMER_CTRL_LEVEL8
10
DIMMER_CTRL_LEVEL9
11
DIMMER_CTRL_LEVEL10
12
DIMMER_CTRL_LEVEL11
13
DIMMER_CTRL_LEVEL12
14
DIMMER_CTRL_LEVEL13
15
DIMMER_CTRL_LEVEL14
16
DIMMER_CTRL_LEVEL15
17
DIMMER_AVERAGE_POINT
18
DIMMER_AVERAGE_DATA
19
DIMMER_LEVEL_AUTO
20
DIMMER_LEVEL_NORMAL
21
DIMMER_LEVEL_ECO
23
VOLTAGE_LEVEL
220
Projector Error Log
0
Warning_Log_1
:
:
49
Warning_Log_50
50
Warning_Log Reset
235
Shutter
0
PRE_MOTION
1
CMP_TRM
2
OUT_DLY_TRM
3
CMP_CHK_CNT
4
OPEN_DLY
5
CLOSE_DLY
6
Position Check Time
7
Stop Mode
240
Flow Calibration
0
Flow Calibration Exe
1
Flow Calibration Error Log
2
Clog Check Enable
241
Flow Ideal Data
0
Flow Ideal Data 1
1
Flow Ideal Data 2
2
Flow Ideal Data 3
3
Flow Ideal Data 4
4
Flow Ideal Data 5
5
Flow Ideal Data 6
Function
0:Auto 1:Manual
Lamp Power Manual Control (DIMMER_CTRL_LEVEL
0(Dark)~15(Bright))
Y Level1 Data for Dimmer
Y Level2 Data for Dimmer
Y Level3 Data for Dimmer
Y Level4 Data for Dimmer
Y Level5 Data for Dimmer
Y Level6 Data for Dimmer
Y Level7 Data for Dimmer
Y Level8 Data for Dimmer
Y Level9 Data for Dimmer
Y Level10 Data for Dimmer
Y Level11 Data for Dimmer
Y Level12 Data for Dimmer
Y Level13 Data for Dimmer
Y Level14 Data for Dimmer
Y Level15 Data for Dimmer
Y Average Point
Y Average Data (Read only)
Current Y Level (Read only)
Dim Level at Normal
Dim Level at Eco
Lamp Voltage (Read only)
Latest Error log
:
50th Error log
Log is cleared when the value is set to 10.
Shutter Warm - up Operation (0: Yes, 1: No)
Chattering Detecting Term
Output Term
Count of Information Sync
Open Output Delay
Close Output Delay
Position Check Time
Shutter Stop Condition
0: Free, 1: Brake
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
(Value will be set after calibration)
Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1
Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2
Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3
Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4
Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5
Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6
Range
0 - 1
0 - 300
1 - 500
0 - 1
0 - 15
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 16
-
-
0 - 15
0 - 15
-
0 - 32767
:
0 - 32767
0 ~ 10
0 - 1
0 - 32767
0 - 32767
0 - 15
0 - 63
0 - 63
1 - 255
0 - 1
0 - 1
-
0 - 1
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
-54-
Initial
Note
1
200
150
0
0
7
14
21
28
35
42
49
56
63
70
77
84
91
98
105
4
-
-
15
0
-
0
:
0
0
Initial: 1 / Shipping: 0
7000
15000
10
0
0
50
0
* Wind sensor calibra-
0
tion.
255
Initial: 0 / Shipping: 1
335
385
440
480
490
1023

Hide quick links: