2
Water
102mm
(14")
810 mm (31-7/8")
Figure 2
LEFT END – WATER & STEAM
Boiler Model
Boiler Length "A"
mm
TR 20
292
378
TR 30
464
TR 40
549
TR 50
635
TR 60
721
TR 70
RATINGS WITH RIELLO BURNER
Boiler
OIL INPUT
Model
Number
*
ml/s USGPH kW
MBH
TR 20 0.79
0.75
31
105
TR 30H 1.05
1.00
41
140
1.15
1.10
45
154
TR 30
1.31
1.25
51
175
TR 40H 1.58
1.50
62
210
1.68
1.60
66
224
TR 40
1.89
1.80
74
252
TR 50H 2.10
2.00
82
280
2.20
2.10
86
294
TR 50
2.47
2.35
96
329
2.73
2.60
107
364
TR 60
3.00
2.85
117
399
3.26
3.10
127
434 104
TR 70
3.52
3.35
137
469 113
Note: Standard working pressure 207 kPa (30 psi) water, 103 kPa
(15 psi) steam.
* ADD SUFFIX
X
Denotes no circulator and no thermostat
P
Packaged water boiler
PT
Packaged water boiler with tankless heater
PZ
Packaged steam boiler less tankless heater
PZT
Packaged steam boiler with tankless heater
§
Tankless heater rating based on intermittent draw.
§§ Nominal clay tile liner dimensions.
Steam
Figure 1
445 mm (17-1/2")
DRAIN COCK
(Alternate 38 mm
(1-1/2") Tapping
32 mm (1-1/4")
for additional
circulator.)
89 mm (3-1/2")
Front to Flue "B"
in
mm
11 1/2
210
8 9/32
14 7/8
255
10 1/32
18 1/4
298
11 23/32
21 5/8
341
13 13/32
25
383
15 3/32
28 3/8
426
16 25/32
HEATING CAPACITY
BURNER NET RATINGS
OUTPUT
Water
Steam
Water‡
kW
MBH
kW
MBH
kW
MBH
kW
27
91
23
79
35
121
31
105
40
134
40
131
35
117
45
151
39
131
53
182
52
179
46
158
58
195
58
195
50
170
64
218
56
190
71
243
70
239
62
211
76
266
75
255
66
223
80
272
67
237
88
298
88
298
77
259
97
327
84
284
352
105
354
90
306
381
98
331
‡
For forced hot water heating systems where the boiler and
all piping are located within the area to be heated, the boiler
may be selected on the basis of gross output capacity. The
net output ratings shown are based on an allowance for
piping and pickup of 1.15 (water) or 1.33 (steam). Gross
output is divided by the allowance to obtain net rating. The
manufacturer should be consulted before selecting a boiler
for unusual piping and pickup requirements such as inter
mittent system operation, extensive piping, etc.
2
Note: m
of steam is equal to net output (W) divided by
757 W (square feet of steam is equal to net output (BTU)
divided by 240 BTUs)
Tapping
Location
Steam Boiler
1
76 mm (3") supply
1A
51 mm (2") supply on rear section
2
second 6 mm (1/4") siphon & pressure
cut-out if required
3
19 mm (3/4") steam safety valve
4
6 mm (1/4") siphon, pressure gauge &
pressure cut-out
5A
—
5B
—
6
—
7
—
8
19 mm (3/4") alternate electronic low
water cut-off
9
38 mm (1-1/2") skimmer tapping
10
13 mm (1/2") low limit for tankless
11A
13 mm (1/2") tankless inlet
11B
13 mm (1/2") tankless outlet
12
13 mm (1/2") steam gauge glass & 67 LWCO
13
38 mm (1-1/2") bushed to 19 mm (3/4") for drain cock
14
38 mm (1-1/2") condensate return
15
3/4" NPT zone tapping
635 mm
(25")
372 mm
(14-5/8")
1
95 mm (3-3/4")
Flue Diameter "C"
in
mm
in
152¶
6¶
152¶
6¶
178
7
203
8
203
8
229
9
CHIMNEY SIZE
Steam
Steam
I.D
MBH
m² Sq.Ft.
mm
in.
30
101
39
421
203 x
8" x 8"
203 x
x 15'
39
134
52
558
4.6m
43
146
56
608
52
179
69
746
56
191
74
796
66
224
87
933
203 x
8" x 12"
305 x
x 15'
4.6m
79
286
103 1108
Water Boiler
38 mm (1-1/2") supply
—
19 mm (3/4") air vent or expansion tank
19 mm (3/4") water relief valve
—
13 mm (1/2") tankless inlet
13 mm (1/2") tankless inlet
6 mm (1/4") pressure temp. gauge
13 mm (1/2") high limit, hi/lo or
combination control
—
—
—
—
—
38 mm (1-1/2") return &
19 mm (3/4") drain cock
38 mm (1-1/2") alternate return
—
1
648 mm
(25-1/2")
Circulator Flange
mm
in
38
1 1/2
38
1 1/2
38
1 1/2
38
1 1/2
38
1 1/2
1172
AFUE %
Boiler
I.D.ROUND
Sections
Water Steam
mm
in.
127 x
5' x 15' 83.50
2
4.6 m
86.00
3
84.85 84.15
3
152 x
6" x15'
4.6m
83.50
86.00 84.00
4
84.45 84.80
4
178 x
7" x 15'
4.6m
83.33
86.00 84.00
5
203 x
8" x 15'
84.06 83.45
5
4.6m
6
254 x
10" x
4.6m
15'
7
†
Ratings apply to the use of light oil at 11,000 W/L (140,000
Btu per gallon), and apply only when burner models listed
on pages 15 17 of this manual are used, and are properly
adjusted to produce 13% CO
.
2
¶
TR 20 Collar is oblong, will fit 152 mm (6") diameter nomi
nal connector.
TR Series
44 mm
(1-3/4")
Overall Length "E"
mm
in
616
24 1/4
702
27 5/8
787
31
873
34 3/8
959
37 3/4
46 1/8"
TANKLESS HEATER
§
Water
Steam
ml/s USGPM ml/s USGPM
139
2.20
189
3.00
202
3.20
189
3.00
214
3.40
240
3.80
215
3.40
221
3.90
221
3.50
261
4.15
278
4.40
246
3.90
277
4.40
252
4.00
296
4.70
309
4.90
284
4.50
328
5.20
343
5.45
315
5.00
359
5.70